1.06035
Metanol
≥99.9% (GC), suitable for LC/MS, LiChrosolv®
Sinónimos:
Alcohol metílico
About This Item
Productos recomendados
product name
Metanol, hypergrade for LC-MS LiChrosolv®
agency
suitable for ASTM® 7968
suitable for ASTM® 7979
suitable for DIN 38407-42
suitable for EPA 1621
suitable for EPA 1633
suitable for EPA 533
suitable for EPA 537.1
suitable for EPA 8327
suitable for EPA ACB B21-02
suitable for EPA ACB B23-05b
suitable for EPA OTM-45
suitable for GB 31604.35-2016
suitable for GB 5009.253-2016
suitable for ISO 21675 2019
suitable for ISO 25101
suitable for ISO/CEN 15968-2010
Quality Level
reg. compliance
suitable for FDA C-010.02
vapor density
1.11 (vs air)
vapor pressure
128 hPa ( 20 °C)
410 mmHg ( 50 °C)
97.68 mmHg ( 20 °C)
product line
LiChrosolv®
assay
≥99.9% (GC)
form
liquid
autoignition temp.
725 °F
potency
5628 mg/kg LD50, oral (Rat)
17100 mg/kg LD50, skin (Rabbit)
expl. lim.
36 %
technique(s)
LC/MS: suitable
impurities
≤0.0002 meq/g Acidity
≤0.0002 meq/g Alkalinity
≤0.01% Water
≤10 ppb Al (Aluminium)
≤10 ppb Ca (Calcium)
≤10 ppb Fe (Iron)
≤10 ppb Mg (Magnesium)
≤100 ppb Na (Sodium)
≤5 ppb Any further metal (ICP-MS)
≤5 ppb K (Potassium)
evapn. residue
≤1.0 mg/L
SMILES string
CO
transmittance
210 nm, ≥35%
220 nm, ≥60%
230 nm, ≥75%
260 nm, ≥98%
refractive index
n20/D 1.329 (lit.)
kinematic viscosity
0.54-0.59 cSt(20 °C)
bp
64.7 °C (lit.)
mp
−98 °C (lit.)
transition temp
flash point 9.7 °C
density
0.791 g/mL at 25 °C (lit.)
format
neat
storage temp.
2-30°C
InChI
1S/CH4O/c1-2/h2H,1H3
InChI key
OKKJLVBELUTLKV-UHFFFAOYSA-N
¿Está buscando productos similares? Visita Guía de comparación de productos
General description
Application
- Composición de los productos químicos y propiedades antiosteogénicas en extractos volátiles del rizoma de Homalomena gigantea: se destaca el papel del metanol en la extracción y el análisis de compuestos orgánicos volátiles de plantas medicinales, proporcionando información valiosa para los investigadores en farmacología y química de productos naturales (Thanh et al., 2024).
- Anión complejo de cromo (III) dinuclear con puente de tartrato homoquiral con un enlace de hidrógeno asistido por resonancia para la conducción de protones: se utiliza el metanol como disolvente en la síntesis de compuestos inorgánicos complejos, que son esenciales para el desarrollo de nuevos materiales para aplicaciones energéticas, como las membranas de intercambio de protones (Dunatov et al., 2024).
Preparation Note
Analysis Note
Identidad (IR): conforme
Residuo de evaporación: ≤ 1,0 mg/l
Agua: ≤ 0,01 %
Acidez: ≤ 0,0002 meq/g
Alcalinidad: ≤ 0,0002 meq/g
Al (Aluminio): ≤ 10 ppb
Ca (Calcio): ≤ 10 ppb
Fe (Hierro): ≤ 10 ppb
K (Potasio): ≤ 5 ppb
Mg (Magnesio): ≤ 10 ppb
Na (Sodio): ≤ 100 ppb
Cualquier otro metal (ICP-MS): ≤ 5 ppb
Calidad de gradiente (a 220 nm): ≤ 2,0 mAU
Grado de gradiente (a 235 nm): ≤ 1,0 mAU
Fluorescencia (como quinina a 254 nm): ≤ 1,0 ppb
Fluorescencia (como quinina a 365 nm): ≤ 0,5 ppb
Transmitancia (a 210 nm): ≥ 35 %
Transmitancia (a 220 nm): ≥ 60 %
Transmitancia (a 230 nm): ≥ 75 %
Transmitancia (desde 260 nm): ≥ 98 %
Adecuado para LC-MS; Intensidad de pico de masa de fondo basada en la reserpina (APCI/ESI positivo): ≤ 2 ppb
Adecuado para LC-MS; Intensidad de pico de masa de fondo basada en la reserpina (APCI/ESI positivo): ≤ 20 ppb
Filtrado a través de un filtro de 0,2 µm
Other Notes
Legal Information
related product
signalword
Danger
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
target_organs
Eyes,Central nervous system
Storage Class
3 - Flammable liquids
wgk_germany
WGK 2
flash_point_f
49.5 °F - closed cup
flash_point_c
9.7 °C - closed cup
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Los clientes también vieron
Artículos
Determination of plasma protein binding using a SupelTM C18 pin device based BioSPME method for efficient sample preparation, along with a comparison to the equilibrium dialysis method.
Determination of plasma protein binding using a SupelTM C18 pin device based BioSPME method for efficient sample preparation, along with a comparison to the equilibrium dialysis method.
Determination of plasma protein binding using a SupelTM C18 pin device based BioSPME method for efficient sample preparation, along with a comparison to the equilibrium dialysis method.
Determination of plasma protein binding using a SupelTM C18 pin device based BioSPME method for efficient sample preparation, along with a comparison to the equilibrium dialysis method.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico