80457
Ácido trifluoroacético
eluent additive for LC-MS, LiChropur™, ≥99.0% (GC)
Sinónimos:
TFA
About This Item
Productos recomendados
grade
eluent additive for LC-MS
Quality Level
vapor density
3.9 (vs air)
vapor pressure
97.5 mmHg ( 20 °C)
assay
≥99.0% (GC)
form
liquid
technique(s)
LC/MS: suitable
impurities
≤0.05% water
≤50 mg/kg total sulfur (as SO4)
refractive index
n20/D 1.3 (lit.)
bp
72.4 °C (lit.)
mp
−15.4 °C (lit.)
density
1.489 g/mL at 20 °C (lit.)
anion traces
chloride (Cl-): ≤50 mg/kg
sulfite (SO32-): ≤10 mg/kg
cation traces
Ag: ≤0.05 mg/kg
Al: ≤0.1 mg/kg
Ba: ≤0.1 mg/kg
Bi: ≤0.5 mg/kg
Ca: ≤0.5 mg/kg
Cd: ≤0.1 mg/kg
Co: ≤0.05 mg/kg
Cr: ≤0.1 mg/kg
Cu: ≤0.05 mg/kg
Fe: ≤1.0 mg/kg
K: ≤1.0 mg/kg
Li: ≤0.1 mg/kg
Mg: ≤1.0 mg/kg
Mn: ≤0.1 mg/kg
Mo: ≤0.05 mg/kg
NH4+: ≤10 mg/kg
Na: ≤1.0 mg/kg
Ni: ≤0.1 mg/kg
Pb: ≤0.05 mg/kg
Sr: ≤0.05 mg/kg
Tl: ≤0.1 mg/kg
Zn: ≤0.1 mg/kg
UV absorption
λ: 260 nm Amax: ≤0.9
λ: 270 nm Amax: ≤0.1
λ: 280 nm Amax: ≤0.08
λ: 290 nm Amax: ≤0.07
λ: 300 nm Amax: ≤0.06
λ: 320 nm Amax: ≤0.05
SMILES string
OC(C(F)(F)F)=O
suitability
passes test for LC-MS
InChI
1S/C2HF3O2/c3-2(4,5)1(6)7/h(H,6,7)
InChI key
DTQVDTLACAAQTR-UHFFFAOYSA-N
¿Está buscando productos similares? Visita Guía de comparación de productos
General description
Features:
- Extensive QC testing ensures the highest specifications.
- Optimized to improve ionization and resolution.
- Extremely low levels of inorganic and organic impurities.
- Manufactured specifically for accurate and fast LC-MS.
Application
Packaging
Legal Information
related product
signalword
Danger
hcodes
Hazard Classifications
Acute Tox. 4 Inhalation - Aquatic Chronic 3 - Eye Dam. 1 - Skin Corr. 1A
Storage Class
8B - Non-combustible corrosive hazardous materials
wgk_germany
WGK 2
flash_point_f
>212.0 °F - Pensky-Martens closed cup
flash_point_c
> 100 °C - Pensky-Martens closed cup
Choose from one of the most recent versions:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Los clientes también vieron
Artículos
The article describes the use of difluoroacetic acid (DFA) as an effective alternative to acid modifiers, formic acid (FA) and trifluoroacetic acid (TFA) in the LC-UV/MS analysis of proteins.
The article describes the use of difluoroacetic acid (DFA) as an effective alternative to acid modifiers, formic acid (FA) and trifluoroacetic acid (TFA) in the LC-UV/MS analysis of proteins.
The article describes the use of difluoroacetic acid (DFA) as an effective alternative to acid modifiers, formic acid (FA) and trifluoroacetic acid (TFA) in the LC-UV/MS analysis of proteins.
The article describes the use of difluoroacetic acid (DFA) as an effective alternative to acid modifiers, formic acid (FA) and trifluoroacetic acid (TFA) in the LC-UV/MS analysis of proteins.
Protocolos
Straightforward HPTLC-MS analysis of lactose in dairy products (milk or yoghurt) using only protein crash, centrifugation and dilution as sample preparation.
Straightforward HPTLC-MS analysis of lactose in dairy products (milk or yoghurt) using only protein crash, centrifugation and dilution as sample preparation.
Straightforward HPTLC-MS analysis of lactose in dairy products (milk or yoghurt) using only protein crash, centrifugation and dilution as sample preparation.
Straightforward HPTLC-MS analysis of lactose in dairy products (milk or yoghurt) using only protein crash, centrifugation and dilution as sample preparation.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico