50295-U
Ascentis® Express 90 Å HILIC (5 μm) HPLC Columns
L × I.D. 5 mm × 2.1 mm, HPLC Guard Cartridge, pkg of 3 ea
About This Item
Empfohlene Produkte
Produktbezeichnung
Ascentis® Express HILIC, 5 μm Guard Cartridge, 5 μm particle size, L × I.D. 5 mm × 2.1 mm, pkg of 3 ea
Materialien
stainless steel column
Qualitätsniveau
Agentur
suitable for USP L3
Produktlinie
Ascentis®
Leistungsmerkmale
endcapped: no
Verpackung
pkg of 3 ea
Methode(n)
HPLC: suitable
LC/MS: suitable
L × ID
5 mm × 2.1 mm
Oberflächenbereich
90 m2/g
Matrix
superficially porous particle
Aktive Matrixgruppe
silica phase
Partikelgröße
5 μm
Porengröße
90 Å
Betriebs-pH-Wert
1-8
Anwendung(en)
food and beverages
Trenntechnik
hydrophilic interaction (HILIC)
normal phase
Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich
Verwandte Kategorien
Allgemeine Beschreibung
Rechtliche Hinweise
Erforderlich, aber nicht bereitgestellt
Lagerklassenschlüssel
11 - Combustible Solids
WGK
WGK 3
Flammpunkt (°F)
Not applicable
Flammpunkt (°C)
Not applicable
Hier finden Sie alle aktuellen Versionen:
Analysenzertifikate (COA)
It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumente section.
Wenn Sie Hilfe benötigen, wenden Sie sich bitte an Kundensupport
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
-
What is the Department of Transportation shipping information for this product?
1 Antwort-
Hilfreich?
-
-
What steps should be taken to maximize column life?
1 Antwort-
To maximize column life, ensure that samples and mobile phases are particle-free. The use of guard columns or an in-line filter with 0.5 μm porosity between the sample injector and the column is highly recommended. The 2 μm porosity frits on Ascentis Express 5 μm HILIC columns are less subject to pluggage than are the 0.5 μm frits typically used with other small-particle columns. Should the operating pressure of the column suddenly increase beyond normal levels, reversing the flow direction of the column may be attempted to remove debris on the inlet frit.