The bags are not permeable and are suitable for storing gases for 2-3 days. However, caution must be observed so as not to over-fill the bags. All gas sampling bags (Tedlar and Supel-Inert) should only be filled to 80% of the volume to prevent overpressure. Filling the bag with pressures greater than 1 psi (~0.07 bar) could cause the bag to burst or leak the sample.
30226-U
Supel™-Inert Multi-Layer Foil
maximum volume 1 L, Screw Cap Valve (SCV), pkg of 10 bags
Synonym(e):
Supel™-Inert Foil 1L SCV Gas Sampling Bag with Thermogreen® LB-2 Septa
About This Item
Empfohlene Produkte
Agentur
NIOSH 6603
OSHA ID-172,ID-210
Beschreibung
Chemically Inert with Light and Moisture Protection
septum replaceable; Thermogreen® LB-2 septa
Produktlinie
Supel™
Verpackung
pkg of 10 bags
Methode(n)
whole air sampling: suitable
Maximales Volumen
1 L
Größe × B × L
× 7 in. × 9 in.
Eignung
suitable for (Biogas and Landfill Gas (LFG))
suitable for (Calibration Mixes and Gas Transfer)
suitable for (Low molecular weight compounds such as methane, CO, CO2, and permanent gases)
suitable for
Anwendung(en)
air monitoring
environmental
industrial hygiene
Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich
Allgemeine Beschreibung
Key Features and Benefits:
- Multi-layer foil composed of two outer layers of aluminum film providing a great barrier to gases permeating through walls of the bag
- Proven low-bleed Thermogreen LB-2 septa installed in the valve fitting
- Chemically inert with moisture and light protection
- Not recommended for low ppm VOCs due to background levels (we recommend the SupelInert PVDF Tedlar alternative film for VOCs)
- Two valve choices available: Screw Cap Valve (SCV) and Push/Pull Lock Valve (PLV)
- 4 sizes: 1 L, 2 L, 5 L, and 10 L
Rechtliche Hinweise
Luftprobennehmer
Lagerklassenschlüssel
11 - Combustible Solids
WGK
WGK 3
Flammpunkt (°F)
Not applicable
Flammpunkt (°C)
Not applicable
Hier finden Sie alle aktuellen Versionen:
Analysenzertifikate (COA)
It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumente section.
Wenn Sie Hilfe benötigen, wenden Sie sich bitte an Kundensupport
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Kunden haben sich ebenfalls angesehen
-
How permeable are they? We are looking at storing hydrogen for 2/3 days in these bags. Is this viable ?
1 Antwort-
Hilfreich?
-
-
Do you sell the septa of these bags separately as well? The manual says septa can be replaced, and the bag reused even after the septum has too many punctures and doesn't seal properly anymore. If you do, I'd like to order septa only.
1 Antwort-
Yes, the septa replacement product number is 29458-U. Please see the link below to access the replacement:
https://www.sigmaaldrich.com/product/supelco/29458uHilfreich?
-
Aktive Filter
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.