Direkt zum Inhalt
Merck

SML2938

Sigma-Aldrich

Vernakalant hydrochloride

≥98% (HPLC)

Synonym(e):

(3R)-1-((1R,2R)-2-(2-(3,4-Dimethoxyphenyl)ethoxy)cyclohexyl)pyrrolidin-3-ol hydrochloride, (3R)-1-[(1R,2R)-2-[2-(3,4-Dimethoxyphenyl)ethoxy]cyclohexyl]-3-pyrrolidinol hydrochloride, RSD 1235, RSD-1235, RSD1235

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Empirische Formel (Hill-System):
C20H31NO4 · HCl
CAS-Nummer:
Molekulargewicht:
385.93
UNSPSC-Code:
12352200
NACRES:
NA.77

Qualitätsniveau

Assay

≥98% (HPLC)

Form

powder

Lagerbedingungen

desiccated

Farbe

white to beige

Löslichkeit

DMSO: 2 mg/mL, clear

Lagertemp.

−20°C

InChI

1S/C20H31NO4.ClH/c1-23-19-8-7-15(13-20(19)24-2)10-12-25-18-6-4-3-5-17(18)21-11-9-16(22)14-21;/h7-8,13,16-18,22H,3-6,9-12,14H2,1-2H3;1H/t16-,17-,18-;/m1./s1

InChIKey

JMHYCBFEEFHTMK-IIUXMCBISA-N

Biochem./physiol. Wirkung

Vernakalant is a multiple ion channel blocker that exerts in vivo anti-fibrillatory (anti-arrhythmic) efficacy (ED50 = 1.5 μmol/kg/min iv. against ischemia-induced arrhythmias in rats) via atrial-selective Kv1.5 blockage (hKv1.5/rKv4.2/rKv4.3 IC50 = 13/38/30 μM at 1Hz & -80 to 60 mV in 200 (Kv1.5) or 400 (Kv4) msec) as well as potential- and rate-dependent Nav1.5 blockade (inward Na current INa IC50 = 9 μM/20 Hz & -80 mV, 31 μM/1Hz & -60 mV, 107 μM/1Hz & -120 mV using HEK hNav1.5 cells).

Lagerklassenschlüssel

11 - Combustible Solids

WGK

WGK 3

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Gerrit Frommeyer et al.
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 19(5), 866-873 (2016-10-06)
The antiarrhythmic drug vernakalant exerts antiarrhythmic effects in atrial fibrillation. Recent experimental data suggest interactions with the late sodium current and antiarrhythmic effects in ventricular arrhythmias. We aimed at investigating whether treatment with vernakalant reduces polymorphic ventricular tachycardia (VT) in
Jonas Goldin Diness et al.
Circulation. Arrhythmia and electrophysiology, 10(10) (2017-10-12)
Evidence has emerged that small-conductance Ca2+-activated K+ (SK) channels constitute a new target for treatment of atrial fibrillation (AF). SK channels are predominantly expressed in the atria as compared with the ventricles. Various marketed antiarrhythmic drugs are limited by ventricular
Rong Chen et al.
Biochemistry, 57(18), 2704-2710 (2018-04-14)
Molecular dynamics simulations are employed to determine the inhibitory mechanisms of three drugs, 5-(4-phenoxybutoxy)psoralen (PAP-1), vernakalant, and flecainide, on the voltage-gated K+ channel Kv1.5, a target for the treatment of cardiac arrhythmia. At neutral pH, PAP-1 is neutral, whereas the
Gerrit Frommeyer et al.
Journal of cardiovascular electrophysiology, 27(10), 1214-1219 (2016-06-11)
Ranolazine has been reported to have an antiarrhythmic potential. The aim of this study was to assess the electrophysiologic effects of ranolazine and to compare its effects to vernakalant in an experimental whole-heart model of short-QT syndrome. Rabbit hearts were
Gerrit Frommeyer et al.
Journal of cardiovascular medicine (Hagerstown, Md.), 18(9), 663-668 (2017-07-12)
Current guidelines recommend vernakalant for pharmacologic cardioversion of recent-onset atrial fibrillation. However, this drug is not established as chronic therapy. In total, 15 rabbit hearts were Langendorff-perfused. A burst pacing protocol-induced atrial fibrillation in 7 of 15 hearts at baseline

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.