Direkt zum Inhalt
Merck

306312

Sigma-Aldrich

Inhibitorentferner

Prepacked column for removing hydroquinone and monomethyl ether hydroquinone

Synonym(e):

Inhibition Removal Agents

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

1 EA
110,00 €
12 EA
692,00 €

110,00 €


Versandbereit am23. April 2025Details


Bulk-Bestellung anfordern

Größe auswählen

Ansicht ändern
1 EA
110,00 €
12 EA
692,00 €

About This Item

MDL-Nummer:
UNSPSC-Code:
12162002
PubChem Substanz-ID:
NACRES:
NA.23

110,00 €


Versandbereit am23. April 2025Details


Bulk-Bestellung anfordern

Dampfdruck

17 mmHg ( 20 °C)

Qualitätsniveau

Form

beads

Säulengröße

17 mm × 240 mm

SMILES String

[Al]21O[Al](O2)O1

InChI

1S/2Al.3O

InChIKey

TWNQGVIAIRXVLR-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Inhibitorenentfernungspackungen und gebrauchsfertige, vorverpackte Einwegsäulen ermöglichen die einfache Entfernung von geringen Inhibitorenmengen, die ansonsten instabilen Reagenzien oder Lösungsmitteln zugegeben werden. R: 20-37 S: 22-38-36
• Geeignet für Anwendungen, bei denen der Stabilisator oder Inhibitor (Hydrochinon (HQ), Hydrochinon-Monomethylether (MEHQ, 4-Methoxyphenol) oder 4-tert-Butylcatechol (TBC)) vor der Verwendung entfernt werden muss.
• Verbrauchte Säulen können entsorgt1 oder wiederverwendet werden, indem die Säule zu ca. 3/4 mit neuem Packungsmaterial gefüllt wird. Nachfüllvolumen für HQ/MEHQ-Säulen: ~21 g Nachfüllvolumen für TBC-Säulen:~30 g.
• Säulenkapazität (ca.):
HQ/MEHQ: 3 l bei 100 ppm
TBC: 4 l bei 15 ppm
• Die Verwendung von TBC-Säulen und -Packungen mit polaren Lösungsmitteln, einschließlich Acrylsäure, wird nicht empfohlen. Für derartige Anwendungen sollte die Vakuumdestillation verwendet werden.
Einfache Anwendung:
1.
Es wird empfohlen, die vorverpackten Glassäulen mit einer geringen Menge Monomer vorzuwaschen.
2. Geben Sie das Monomer (oder Lösungsmittel) in einen Zugabetrichter, der über der Säule befestigt wird.
3. Geben Sie das Monomer tröpfchenweise in die Säule. Beobachten Sie die zugeführte Menge, um ein Überlaufen der Säule zu vermeiden. Fangen Sie das Monomer in einem geeigneten Behälter auf.
4. Achten Sie darauf, dass die Säulentemperatur bei Feststoff-Monomeren mit niedrigem Schmelzpunkt während der Verwendung über dem Schmelzpunkt liegt.
Achtung: Eine Überhitzung kann zu einer Polymerisierung an der Säule führen. Viskose Monomere oder Monomere mit hohem Schmelzpunkt können vor der Säulenzugabe in einem geeigneten Lösungsmittel verdünnt werden.
1Nicht verbrauchte Säulen können zusammen mit anderen chemischen Feststoffabfällen entsorgt werden. Nach der Verwendung müssen die Toxizität und andere mit dem Monomer, von dem der Inhibitor entfernt wurde, verbundenen Gefahren bei Entscheidungen hinsichtlich der Entsorgung des Packungsmaterials und der Säule berücksichtigt werden.

Anwendung

Inhibitor remover is mainly used in the purification of methyl methacrylate monomer (MMA) and the removal of hydroquinone, which can be used for the synthesis of polymethyl methacrylate (PMMA).[1][2] It can also be used to purify and remove the inhibitor in N,N-dimethylacrylamide (DMAA) and hydroxylethyl methacrylate (HEMA), that can be used to fabricate a low-cost absorbent for metal absorption.[3]

Lagerklassenschlüssel

11 - Combustible Solids

WGK

WGK 3

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable

Persönliche Schutzausrüstung

Eyeshields, Gloves, type N95 (US)


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Lead (II) removal by poly (N, N-dimethylacrylamide-co-2-hydroxyethyl methacrylate)
Ramos-Jacques AL, et al.
European Polymer Journal, 101, 262-272 (2018)
Study on the rheological and electrical properties of PMMA/MWCNT nanocomposites prepared by in situ polymerization assisted by sonication.
Junior VAA, et al.
AIP Conference Proceedings, 1981(1), 020077-020077 (2018)
Electrically conductive nanocomposites of PMMA and carbon nanotubes prepared by in situ polymerization under probe sonication.
Bressanin JM, et al.
Chemical Papers, 1-12 (2018)
Tibor Renkecz et al.
ACS applied materials & interfaces, 5(17), 8537-8545 (2013-08-22)
A versatile approach for the preparation of photoswitchable molecularly imprinted polymers (MIPs) is proposed where the selective recognition and the photoresponsive function are assumed by two different monomers. As a proof of concept, MIP microspheres were synthesized by precipitation polymerization
Subir Ghosh et al.
Journal of the mechanical behavior of biomedical materials, 87, 312-324 (2018-08-14)
A significant number of hip replacements (HR) fail permanently despite the success of the medical procedure, due to wear and progressive loss of osseointegration of implants. An ideal model should consist of materials with a high resistance to wear and

Artikel

An article regarding common FAQs for initiators and stabilizers.

Fragen

1-9 von 9 Fragen  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 Antwort
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Hilfreich?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 Antwort
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Hilfreich?

  3. Would these work for removal of Topanol A, 2,4-Dimethyl-6-tert-butylphenol CAS Number:1879-09-0?

    1 Antwort
    1. This product is not tested for removal of Topanol A, but is expected to be suitable. The product is used for inhibitor removal for product 276685. Methacrylic anhydride, which contains 2,000 ppm Topanol A as inhibitor.

      Hilfreich?

  4. Which side of the column is the top versus the bottom?

    1 Antwort
    1. The label is placed at the top of the column and will include the lot number. The column is provided with a cap on each end; these caps would need to be removed when the column is in use, but replaced between uses.

      The glass wool plugs are present to hold the beads inside the column. Initially, a small volume of liquid will wet the glass wool. As more volume is added, the column will become saturated and then eventually pass through and out at the bottom of the column.

      Hilfreich?

  5. Can Product 306312, Inhibitor removers - Prepacked column for removing hydroquinone and monomethyl ether hydroquinone, be used to remove butylated hydroxytoluene (BHT)?

    1 Antwort
    1. This inhibitor remover is not intended to remove BHT present in a monomer solution; little, if any, BHT will be removed with this column. Unfortunately, Sigma-Aldrich does not currently offer a inhibitor-remover column that will accomplish this purpose.

      Hilfreich?

  6. How much can Product 306312, Inhibitor removers - Prepacked column for removing hydroquinone and monomethyl ether hydroquinone, hold at one time?

    1 Antwort
    1. This product has a bed volume of approximately 30 mL.

      Hilfreich?

  7. Can Product 306312, Inhibitor removers - Prepacked column for removing hydroquinone and monomethyl ether hydroquinone, be used more than once?

    1 Antwort
    1. This pre-packed inhibitor remover column is meant for single use but can be rinsed and reused. If time will pass between uses, this column can be rinsed with methanol, dried, capped on both ends, and stored in a tightly sealed plastic bag in the freezer at -20°C.

      Hilfreich?

  8. What is the flow rate for Product 306312, Inhibitor removers - Prepacked column for removing hydroquinone and monomethyl ether hydroquinone?

    1 Antwort
    1. According to the manufacturer of this inhibitor removal column, the maximum recommended flow rate is 4 bed volumes (approximately 120 mL) per hour.

      Hilfreich?

  9. What is the Department of Transportation shipping information for this product?

    1 Antwort
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Hilfreich?

Bewertungen

Kein Beurteilungswert

Aktive Filter

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.