Přejít k obsahu
Merck

Přeskočit na

10357

Amberlite XAD®-2

pkg of 500 g

Přihlásit pro zobrazení organizačních a smluvních cen.

Vybrat velikost

Změnit zobrazení
Vám/Skladová položkaDostupnostCena
500 g
Obraťte se na zákaznický servis a vyžádejte si informaci o dostupnosti.
8 040,00 Kč

O této položce

Číslo CAS:
MDL number:
UNSPSC Code:
23151817
NACRES:
NB.21

8 040,00 Kč


Obraťte se na zákaznický servis a vyžádejte si informaci o dostupnosti.

Požádejte o zakázkovou objednávku
Technický servis
Potřebujete pomoc? Náš tým zkušených odborníků je vám k dispozici.
Dovolte nám, abychom vám pomohli


Quality Segment

agency

suitable for ASTM® D4861, suitable for EPA Method 10A, Method 23 and OTM-45

form

beads (small)

packaging

pkg of 500 g

technique(s)

HPLC: suitable, LPLC: suitable

surface area

~300 m2/g

matrix

styrene-divinylbenzene (macroreticular)

matrix active group

polymer

particle size

20-60 mesh

pore size

~0.65 mL/g pore volume, 90 Å mean pore size

density

1.02 g/mL at 25 °C (true wet)(lit.), 1.08 g/mL at 25 °C (skeletal)(lit.)

separation technique

reversed phase

storage temp.

2-8°C

SMILES string

N([C@@H](CCC(=O)OC(C)(C)C)C=O)C(=O)OCC1c2c(cccc2)c3c1cccc3

InChI

1S/C24H27NO5/c1-24(2,3)30-22(27)13-12-16(14-26)25-23(28)29-15-21-19-10-6-4-8-17(19)18-9-5-7-11-20(18)21/h4-11,14,16,21H,12-13,15H2,1-3H3,(H,25,28)/t16-/m0/s1

InChI key

BCIPGSZQUDLGSY-INIZCTEOSA-N

General description

Amberlite XAD-2, a hydrophobic copolymer of styrene-divinylbenzene resin, requires longer purification process and is used as a sorbent. Amberlite XAD-2 resin depending upon the aromaticity and size of the hydrophobic groups sorbs organic compounds through low-energy physical interactions.
Nonionic macroreticular resin that adsorbs and releases ionic species through hydrophobic and polar interactions; usually used under isocratic conditions.
Specifications:

Application

Amberlite XAD®-2 was used:
  • as adsorbent in the extraction of organochlorine compounds using Soxhlat extraction technique
  • as adsorbent in the extraction of honey samples using column chromatography for HPLC analysis
  • in adsorption chromatography
Polyaromatic adsorbent resin for hydrophobic compounds up to MW 20,000: phenols, organic removal, surfactants, aroma compounds, antibiotic recovery. May be used as support for catalyst or metals removal. For cleaned US EPA versions, see Supelpak-2 and Supelpak-2B.
     

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
Amberlite is a trademark of DuPont de Nemours, Inc.
XAD is a registered trademark of The Dow Chemical Company or an affiliated company of Dow

Porovnat podobné položky

Zobrazit úplné porovnání

Zobrazit rozdíly

1 of 1

Tato položka
20275SU85300552672U
description

pkg of 500 g

description

pkg of 100 g

description

pkg of 5 kg

description

pkg of 10 kg

matrix

styrene-divinylbenzene (macroreticular)

matrix

styrene-divinylbenzene (macroreticular)

matrix

styrene-divinylbenzene (macroreticular)

matrix

styrene-divinylbenzene (macroreticular)

separation technique

reversed phase

separation technique

reversed phase

separation technique

reversed phase

separation technique

reversed phase

pore size

~0.65 mL/g pore volume, 90 Å mean pore size

pore size

~0.65 mL/g pore volume, 90 Å mean pore size

pore size

~0.65 mL/g pore volume, 90 Å mean pore size

pore size

~0.65 mL/g pore volume, 90 Å mean pore size

matrix active group

polymer

matrix active group

polymer

matrix active group

polymer

matrix active group

polymer

particle size

20-60 mesh

particle size

20-60 mesh

particle size

20-60 mesh

particle size

20-60 mesh

form

beads (small)

form

solid

form

solid

form

solid


Still not finding the right product?

Explore all of our products under Amberlite XAD®-2


Skladovací třída

11 - Combustible Solids

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)



Vyberte jednu z posledních verzí:

Osvědčení o analýze (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumenty section.

Potřebujete-li pomoc, obraťte se na Zákaznická podpora

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů



Questions

1–9 of 9 Questions  
  1. I want to isolate the flavonoids from the plant extract. I need 100g of Amberlite XAD 2. Can you provide it? can i use this isolation of flavonoids

    1 answer
    1. Amberlite™ XAD 2 may be used for isolating flavonoids from plant extracts, as it is a hydrophobic resin commonly utilized for polyphenolic purification. This product is available in several package sizes, including a 100 G package as product 20275. Please see the link below to review all package sizes available, as well as a publication regarding the isolation of flavonoids:
      https://www.sigmaaldrich.com/tech-docs/paper/432232

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  3. Does Amberlite XAD-2 work as a sorbent for VOCs with further thermodesorption to GC-FID?

    1 answer
    1. The Amberlite™ XAD®-2 sorbent has been used for the adsorption of volatile organic compounds from both aqueous and organic solvents, as well as from gas-phase samples. Thermal desorption is possible for GC-FID analysis; however, temperature limitations should be noted. Volatile residues may be emitted from the resin at temperatures above 150 °C, and the resin will begin to pyrolyze at 250 °C. For applications requiring higher temperatures, a graphitized carbon sorbent is recommended.

      Helpful?

  4. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  5. What is the most approriate protocol to wash Amberlite before use? Thanks in advance!

    1 answer
    1. Amberlite XAD-2 is a crude preparation and must be thoroughly cleaned prior to use.

      1. Rinse with hot deionized water (may hold in nylon filter cloth to retain particles) - use at least 3 bed volumes per hour at 110 deg C
      2. Soak overnight in 2 bed volumes (BV) of ethanol.
      3. Load resin into a glass column and rinsed with a further 2 BV of ethanol.
      4. Rinse with 2 BV of deionized water to remove the ethanol, 1 BV of 4% (w/v) sodium hydroxide, 2 BV of deionized water, 1 BV 4% (v/v) hydrochloric acid, and finally rinse with deionized water until the pH of the eluent is neutral.

      For further use it is advantageous to do a wash in the same solvent use in the application.
      Store in sealed container; may be refrigerated but NOT frozen. As a bacteriostat, one may rinse with 20% ethanol (deionized water) prior to storage.

      Helpful?

  6. Is Amberlite XAD-2 ready-to-use?

    1 answer
    1. No.  Amberlite XAD2 is shipped imbibed with 5% NaCl & 1% NaCO3; it has not been specially processed nor cleaned. We suggest that it be extensively treated to a suitable preliminary elution and wash.

      Helpful?

  7. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  8. May I purchase Amberlite XAD-2 in large quantities?

    1 answer
    1. The largest package size of Amberlite XAD2 is 25 kg (Product No. 3025-U).

      Helpful?

  9. Do you offer a precleaned Amberlite XAD-2?

    1 answer
    1. Yes.  Supelco cleans Amberlite XAD2 for a variety of environmental applications.

      Helpful?

Reviews

No rating value

Active Filters