GE17-5079-01
HiTrap® rprotein A Fast Flow
Cytiva 17-5079-01, pack of 5 × 1 mL
About This Item
Doporučené produkty
ligand
recombinant protein A (E. coli)
packaging
pack of 5 × 1 mL
manufacturer/tradename
Cytiva 17-5079-01
storage condition
(20% Ehtanol)
(20% Ethanol)
parameter
<4 mL/min flow rate
42 psi
bed size
7 mm × 25 mm
bed volume
1 mL
column I.D.
7 mm
matrix
4% cross-linked agarose
particle size
60-165 μm
average diameter
90 μm (d50v)
cleaning
2-11
working range
3-10
capacity
~50 mg binding capacity (human lgG/ml medium)
suitability
suitable for bioprocess medium
storage temp.
2-8°C
General description
The recombinant protein A ligand (produced in E. coli) is coupled to Sepharose™ Fast Flow by a technique which generates a stable thioether linkage between rProtein A and the base matrix. The coupling technique is optimized to give high binding capacity for IgG.
Features and Benefits
- Quick, convenient preparative purification of monoclonal antibodies.
- Well-established protein A-based medium used in many approved MAb processes.
- Recombinant protein A exhibits similar Fc region specificity to that of native protein A but shows enhanced binding capacity and fewer regulatory concerns due to the total absence of mammalian culture in the ligand production and purification.
- Simple operations with a syringe, pump, or high-performance chromatography system, such as AKTA design.
Storage and Stability
Analysis Note
Other Notes
Legal Information
related product
signalword
Warning
hcodes
Storage Class
3 - Flammable liquids
Osvědčení o analýze (COA)
Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Zákazníci si také prohlíželi
Sortimentní položky
This page shows how to purify IgM antibodies by affinity chromatography using HiTrap™ IgM Purification HP.
This page shows how to separate IgG antibodies by affinity chromatography using HiTrap® Protein G HP columns from Cytiva.
This page shows various purification options for Protein A Sepharose chromatography media and describes typical binding and elution conditions for Protein A Sepharose chromatography media.
This page shows how to solve practical problems that may occur when running an affinity chromatography column.
Protokoly
Protein A, coupled to Sepharose, binds IgG via its Fc regions, facilitating affinity chromatography purification.
This page shows how to convert between linear flow and volumetric flow rates in affinity chromatography.
How to perform buffer exchange and desalting with Sephadex G-25, HiTrap Desalting columns, or ÄKTAprime plus.
This page shows how to perform column packing and preparation for affinity chromatography when using Tricorn™ or XK columns available from Cytiva.
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.