96665
Potassium Standard for AAS
TraceCERT®, 1 g/L K in nitric acid (nominal concentration)
Synonyma:
Potassium Atomic Absorption Standard
Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen
About This Item
Doporučené produkty
grade
certified reference material
TraceCERT®
Quality Level
product line
TraceCERT®
concentration
1 g/L K in nitric acid (nominal concentration)
technique(s)
AAS: suitable
application(s)
industrial qc
pharmaceutical
format
single component solution
General description
This certified reference material (CRM) is produced in accordance with ISO 17034 and characterized in accordance with ISO/IEC 17025. This CRM is traceable to SI unit kg and measured against primary material from a National Metrology Institute (NMI), e.g. NIST.
Please visit ISO certificates and Site Quality Self-Assessments to access the current certificates of accreditation.
Download your certificate at http://www.sigma-aldrich.com to view certified values, including uncertainty and expiry date.
Please visit ISO certificates and Site Quality Self-Assessments to access the current certificates of accreditation.
Download your certificate at http://www.sigma-aldrich.com to view certified values, including uncertainty and expiry date.
Application
Potassium standard has been used as a calibration standard to determine the concentration of potassium present in minced beef using atomic absorption spectrophotometry(AAS).
Analysis Note
1 g/L K in 2% nitric acid, prepared with high purity KNO3, HNO3 and water
Other Notes
For a complete product listing of our TraceCERT® range of CRMs for ICP and AAS, technical information, and example certificates please visit our ICP & AAS standards website
Legal Information
TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany
signalword
Warning
hcodes
Hazard Classifications
Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2
Storage Class
8B - Non-combustible corrosive hazardous materials
wgk_germany
nwg
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter
Vyberte jednu z posledních verzí:
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Zákazníci si také prohlíželi
Laser Induced Breakdown Spectroscopy for quantification of sodium and potassium in minced beef: a potential technique for detecting beef kidney adulteration
Analytical Methods : Advancing Methods and Applications (2017)
Laser Induced Breakdown Spectroscopy for quantification of sodium and potassium in minced beef: a potential technique for detecting beef kidney adulteration.
Analytical Methods : Advancing Methods and Applications, 9(22), 3314-3322 (2017)
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.