81506
Poly(methyl methacrylate) standard ReadyCal set Mp ~800-2′200′000
for GPC
Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen
About This Item
Doporučené produkty
grade
for GPC
Quality Level
shelf life
limited shelf life, expiry date on the label
technique(s)
gel permeation chromatography (GPC): suitable
format
neat
storage temp.
2-8°C
Application
- PMMA molecular weight calibration in medical device manufacturing: High molecular weight PMMA is used in the stereolithography fabrication of medical devices, ensuring precise control over polymer properties for innovative therapeutic applications (Drizdal et al., 2012).
- Biopolymer size characterization for protein analysis: PMMA standards are essential in the development of miniaturized gel electrophoresis devices, facilitating the analysis of proteins which is pivotal in pharmaceutical research and diagnostic applications (Demianova et al., 2008).
Packaging
1 set contains 30 vials for 10 complete calibrations
Components
ReadyCal Standards are polymer cocktails pre-weighed into autosampler vials for the convenient calibration of GPC/SEC/GFC systems.
This kit contains 10 sets of 3 color-coded vials, each containing four polymethyl methacrylates of different molar masses. Molar masses range from ~800 to ~2,200,000 Da and are carefully selected so that polymer traces are baseline separated.
Each kit contains sufficient material for at least 10 calibrations and includes an instruction manual and calibration curve with measurement conditions.
Suitable for calibrations in THF, toluene, HFIP, acetone, DMF, DMAc, DMSO, chloroform and NMP.
This kit contains 10 sets of 3 color-coded vials, each containing four polymethyl methacrylates of different molar masses. Molar masses range from ~800 to ~2,200,000 Da and are carefully selected so that polymer traces are baseline separated.
Each kit contains sufficient material for at least 10 calibrations and includes an instruction manual and calibration curve with measurement conditions.
Suitable for calibrations in THF, toluene, HFIP, acetone, DMF, DMAc, DMSO, chloroform and NMP.
Storage Class
11 - Combustible Solids
wgk_germany
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Eyeshields, Gloves, type N95 (US)
Vyberte jednu z posledních verzí:
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Zákazníci si také prohlíželi
mSphere, 5(5) (2020-09-11)
The major surface lipophosphoglycan (LPG) of Leishmania parasites is critical to vector competence in restrictive sand fly vectors in mediating Leishmania attachment to the midgut epithelium, considered essential to parasite survival and development. However, the relevance of LPG for sand
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.