Přejít k obsahu
Merck

Přeskočit na

SCT277

BioTracker Red pH-Independent Autophagy Live Cell Probe

Human

Synonyma:

autophagosome live cell probe, red AP live cell probe, red autophagosome probe, red autophagy probe

Přihlásit pro zobrazení organizačních a smluvních cen.

Vybrat velikost

Změnit zobrazení
Velikost baleníSkladová položkaDostupnostCena
5 nmol

K dispozici k odeslání DNESodAreál Kühne+Nagel spol. s r.o.

9 840,00 Kč

O této položce

UNSPSC Code:
41106514
NACRES:
NA.47
Biological source:
human
Manufacturer/tradename:
Millipore

9 840,00 Kč


K dispozici k odeslání DNESpodrobné informace


Technický servis
Potřebujete pomoc? Náš tým zkušených odborníků je vám k dispozici.
Dovolte nám, abychom vám pomohli

Název produktu

BioTracker Red pH-Independent Autophagy Live Cell Probe,

biological source

human

Quality Level

packaging

vial of 5 nmol

manufacturer/tradename

Millipore

technique(s)

cell culture | stem cell: suitable, flow cytometry: suitable

shipped in

2-8°C

storage temp.

2-8°C

General description

BioTracker Red pH-Independent Autophagy Live Cell Probe detects autophagosomes and autolysosomes. The presumptive mechanism involves incorporation of the probe via structural features into the autophagosome during double-membrane formation. Upon incorporation, the probe emits fluorescence under hydrophobic conditions. The utility of the probe is conferred by molecular properties that include cell permeability, does not require transfection, and enables live cell detection with fluorescence microscopy or other fluorescence capture instruments.
The small fluorescent molecule SCT277 is used to detect autophagosomes and autolysosomes. The presumed mechanism is that the dye is incorporated into the autophagosome during double-membrane formation via structural features, and then emits fluorescence under hydrophobic conditions. The probe emits in the far red range.SPECTRAL CHARACTERISTICS: Excitation λ: 530 nmEmission λ: 720 nm

Features and Benefits

Fluorescence microscopyFlow cytometry

Preparation Note

Store at 2-8 °C, protected from light.

Other Notes

SCT277 detects autophagosomes and autolysosomes by the likely mechanism of incorporation into the autophagosome during double membrane formation, and emits red fluorescence under hydrophobic conditions. SCT277 is cell permeable, does not require transfection, and enables live cell imaging with fluorescence microscopy and quantitative assay by flow cytometry.Add 50 uL DMSO to tube of SCT277 (5 nmol) and pipet to dissolve to make a 0.1 mM stock solution. Dilute with culture medium to 0.1 - 0.5 uM to make working solution.

Legal Information

BioTracker is a trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Skladovací třída

11 - Combustible Solids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable


Osvědčení o analýze (COA)

Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Globální číslo obchodní položky

Skladová položkaGTIN
SCT27704065269218579

Questions

Reviews

No rating value

Active Filters

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis