Přejít k obsahu
Merck

Přeskočit na

P3C010C05

Pellicon® 3 Cassette with Ultracel® Membrane

filtration area 0.57 m2, NMWCO 10 kDa

Synonyma:

Pellicon® 3 Cassette with Ultracel 10 kDa Membrane, C screen, 0.57 m2

Přihlásit pro zobrazení organizačních a smluvních cen.

Vybrat velikost

Změnit zobrazení
Vám/SKUDostupnostCena
1 ea

Očekávané datum odeslání16. září 2026odAreál Kühne+Nagel spol. s r.o.

104 000,00 Kč

O této položce

eCl@ss:
32031602
UNSPSC Code:
41104903

104 000,00 Kč


Očekávané datum odeslání16. září 2026podrobné informace


Technický servis
Potřebujete pomoc? Náš tým zkušených odborníků je vám k dispozici.
Dovolte nám, abychom vám pomohli


Quality Segment

material

TPE seal, composite regenerated cellulose (CRC) , polypropylene screen, stainless steel cap (for end; polypropylene-encapsulated)

feature

holdup volume 85 mL (in feed channel)

manufacturer/tradename

Pellicon®

parameter

30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C

technique(s)

analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration)

H

2.4 cm (0.93 in.)

L

20.6 cm (8.1 in.)

W

17.8 cm (7 in.)

filtration area

0.57 m2

membrane area

0.57 m2

gravimetric extractables

≤1500 mg/m2

matrix

Ultracel® (Membrane)

pore size

10 kDa NMWCO

pH

2-13

General description

Pellicon® 3 filtration devices are advanced, high-performance cassettes ideal for today’s higher titer therapeutic antibodies as well as the more demanding filtration processes that require higher operating pressures, temperatures and caustic cleaning regimes.

The Pellicon® 3 Cassette with Ultracel® Membrane is designed for the filtration of therapeutic proteins (such as monoclonal antibodies) and recombinant and non-recombinant proteins.

This P3C010C05 Pellicon® 3 ultrafiltration device features a pore size of 10 kDa NMWCO, a filtration area of 0.57 m2, a PLCGC membrane, and dimensions measuring 2.3 cm (H) x 5.6 cm (W) x 20.6 cm (L).

Features and Benefits

  • Rugged & reliable – ideally suited for today′s more demanding filtration processes
  • High performance – produces excellent resolution, yields and back-pressure resistance
  • Optimum product recovery – thanks to proven membrane technology
  • Void-free technology – leading-edge membranes resolve virtually any separation challenge
  • Defect-free, superior adhesion – Ultracel®uses composite membranes cast on a microporous substrate
  • Automated manufacturing – delivers unbeatable performance, consistency and reliability
  • Easy installation & care – simple to install and maintain

Analysis Note

Gravimetric Extractables: after 24 hours in water at controlled room temperature

Other Notes

These products are manufactured in a facility which adheres to Good Manufacturing Practices.

Legal Information

Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany
ULTRACEL is a registered trademark of Merck KGaA, Darmstadt, Germany

Porovnat podobné položky

Zobrazit úplné porovnání

Zobrazit rozdíly

1 of 1

Tato položka
P3C010C01P3C030C01P3C003C05
description

filtration area 0.57 m2, NMWCO 10 kDa

description

filtration area 0.11 m2, NMWCO 10 kDa

description

filtration area 0.11 m2, NMWCO 30 kDa

description

filtration area 0.57 m2, NMWCO 3 kDa

pore size

10 kDa NMWCO

pore size

10 kDa NMWCO

pore size

30 kDa NMWCO

pore size

3 kDa NMWCO

technique(s)

buffer exchange: suitable, protein purification: suitable (concentration), analytical sample preparation: suitable

technique(s)

buffer exchange: suitable, protein purification: suitable (concentration), analytical sample preparation: suitable

technique(s)

analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration)

technique(s)

buffer exchange: suitable, analytical sample preparation: suitable, protein purification: suitable (concentration)

filtration area

0.57 m2

filtration area

0.11 m2

filtration area

0.11 m2

filtration area

0.57 m2

matrix

Ultracel® (Membrane)

matrix

Ultracel® (Membrane)

matrix

Ultracel® (Membrane)

matrix

Ultracel® (Membrane)

material

composite regenerated cellulose (CRC) , polypropylene screen, TPE seal, stainless steel cap (for end; polypropylene-encapsulated)

material

polypropylene screen, polypropylene cap (for end), composite regenerated cellulose (CRC) , TPE seal

material

composite regenerated cellulose (CRC) , TPE seal, polypropylene cap (for end), polypropylene screen

material

polypropylene screen, TPE seal, stainless steel cap (for end; polypropylene-encapsulated), composite regenerated cellulose (CRC)

parameter

6.9 bar max. inlet pressure (100 psi), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 80 psi max. transmembrane pressure at 4-40 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours)

parameter

80 psi max. transmembrane pressure at 4-40 °C, 4-6 L/min-m2 recirculation rate, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi)

parameter

6.9 bar max. inlet pressure (100 psi), 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 80 psi max. transmembrane pressure at 4-40 °C, 40 psi max. transmembrane pressure at 4-50 °C, 4-6 L/min-m2 recirculation rate

parameter

80 psi max. transmembrane pressure at 4-40 °C, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate


Still not finding the right product?


Skladovací třída

10 - Combustible liquids

wgk

WGK 2


Seznamy omezení vyplývajících z předpisů

Seznamy omezení vyplývajících z předpisů jsou poskytovány zejména pro chemické produkty. Pro jiné než chemické produkty lze poskytovat pouze omezené informace. Žádný záznam znamená, že v seznamech není obsažena žádná ze součástí. Povinností uživatele je zajistit bezpečné a zákonné použití produktu.

64-19-7

CAS No.


Dodržování zásad SVP pomocí programu Emprove®

Urychlete kvalifikaci, zajistěte shodu s předpisy a ušetřete čas s nástrojem Emprove® Dossiers.

Stáhnout Dossiers

Poznámka: budete přeneseni na stránky EmproveSuite.com. Vaše uživatelské jméno a heslo jsou oddělené od stránek SigmaAldrich.com a mohou se lišit.

Zaregistrujte se zdarma a získejte přístup k Emprove® Dossiers během několika minut. Upgradujte svůj plán předplatného a odemkněte si pokročilý a přizpůsobený obsah v Emprove® Suite.

Nenašli jste, co jste hledali? Navštivte stránku nápovědy programu Emprove®..

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Máte potíže při hledání svého čísla produktu nebo šarže/dávky?

Při zobrazení na webových stránkách jsou čísla produktů zkombinována s velikostí balení / množstvím (příklad: T1503-25G). Ujistěte se, že v poli Číslo produktu zadáváte POUZE číslo produktu (příklad: T1503).

Example:

T1503
Číslo produktu
-
25G
Velikost balení / množství

Další příklady:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

zadat jako 1.000309185)

Having trouble? Feel free to contact Technický servis pro pomoc



Questions

Reviews

No rating value

Active Filters