MADCYMAG-72K
MILLIPLEX® Mouse Adipocyte Magnetic Panel - Endocrine Multiplex Assay
The analytes available for this multiplex kit are: Adiponectin, IL-6, Leptin, MCP-1, PAI-1 (Total), Resistin, TNF-α.
About This Item
Doporučené produkty
Quality Level
species reactivity
mouse
manufacturer/tradename
Milliplex®
assay range
accuracy: 85-98%
standard curve range: 12.2-50,000 pg/mL
technique(s)
multiplexing: suitable
detection method
fluorometric (Luminex xMAP)
shipped in
wet ice
Související kategorie
General description
MILLIPLEX® Mouse Adipocyte Panel is a 7-plex kits used for the simultaneous quantification of any or all of the following analytes in mouse tissue culture supernatant samples: Adiponectin, IL-6, Leptin, MCP-1, PAI-1 Total, Resistin and TNFα. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Metabolism
Application
- Analytes: Adiponectin, IL-6, Leptin, MCP-1, PAI-1 (Total), Resistin, TNFα
- Recommended Sample Type: Mouse tissue culture supernatants
- Recommended Sample Dilution: 10 μL per well of tissue culture supernatant; dilution with an appropriate control medium may be required.
- Assay Run Time: Overnight (16-18 hours) at 2-8°C or 2 hours at room temperature (20-25°C).
- Research Category: Metabolism
- Research Subcategory: Endocrine, Obesity, Metabolic Disorders
Features and Benefits
Other Notes
Legal Information
signalword
Warning
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1
Storage Class
10 - Combustible liquids
Osvědčení o analýze (COA)
Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Související obsah
Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.