Přejít k obsahu
Merck

KVEPS015FB3

Millipore Express® SHR 0.1µm, Opticap® XL 150 Capsule

Fittings 3/4 in. TC- 9/16 in. HB with Bell, Sterile

Synonyma:

Millipore Express® SHR, Opticap® XL Capsule

Přihlásit pro zobrazení organizačních a smluvních cen.

Vybrat velikost

Změnit zobrazení

O této položce

UNSPSC Code:
23151806
Technický servis
Potřebujete pomoc? Náš tým zkušených odborníků je vám k dispozici.
Dovolte nám, abychom vám pomohli


Název produktu

Opticap® XL 150 CapsuleMedia: Sterile Millipore Express® SHR 0.1 µm, Chemistry: Hydrophilic Polyethersulfone (PES)Inlet: 3/4 in. Sanitary FlangeOutlet: 9/16 in. Hose Barb with BellMax Operating Pressure: 80 psi @ 25 °C

Quality Segment

material

polyethylene support, polypropylene device, polypropylene housing, polypropylene vent cap, silicone seal

reg. compliance

meets FDA 21 CFR 177-182 (all component materials)

sterility

irradiated, sterile

product line

Opticap® XL 150

feature

hydrophilic

manufacturer/tradename

Millipore Express®

parameter

≤1.4 mL/min air diffusion at 3.45 bar (50 psig) (in water), 1.0 bar max. differential pressure (15 psid) at 80 °C (Forward), 1.0 bar max. inlet pressure (15 psi) at 80 °C, 100 psi max. differential pressure (6.9 bar) (intermittent), 2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent), 2.75 bar max. inlet pressure (40 psi) at 60 °C, 25 °C max. inlet temp., 5.5 bar max. differential pressure (80 psid) at 25 °C (Forward), 5.5 bar max. inlet pressure (80 psi) at 23 °C, 6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent), 6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent), 80 psi max. differential pressure (5.5 bar) (continuous), 80 psig max. inlet pressure

technique(s)

sterile filtration: suitable

cartridge nominal length

3.8 in. (9.7 cm)

device L

9.7 cm (3.8 in.)

filter diam.

5.6 cm (2.2 in.)

filter filtration area

250 cm2

impurities

≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction), <0.25 EU/mL USP bacterial endotoxins (sample aqueous extraction)

matrix

Millipore Express® SHR

pore size

0.1 μm pore size

bubble point

≥4000 mbar (58 psig), air with water

fitting

(19 mm (¾ in.) Sanitary Flange Inlet and 14 mm (9/16 in.) Hose Barb Outlet with filling bell)

General description

Device Configuration: Capsule

Packaging

Double Easy-Open bag

Preparation Note

Sterilization Method:
3 autoclave cycles of 60 min at 123 °C; not in-line steam sterilizable
This product was manufactured with a MILLIPORE EXPRESS® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Analysis Note

Bacterial Retention: Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 107 CFU/cm2 using ASTM® F838 methodology.
TOC/Conductivity: After sterilization and a controlled water flush of 2.0 L, samples exhibited &#x3C 500 ppb TOC per USP &#x3C 643 &#x3C and &#x3C 1.3 μS/cm per USP &#x3C 645 &#x3C at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥ 1 L

Other Notes

Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany


Still not finding the right product?




Dodržování zásad SVP pomocí programu Emprove®

Urychlete kvalifikaci, zajistěte shodu s předpisy a ušetřete čas s nástrojem Emprove® Dossiers.

Stáhnout Dossiers

Poznámka: budete přeneseni na stránky EmproveSuite.com. Vaše uživatelské jméno a heslo jsou oddělené od stránek SigmaAldrich.com a mohou se lišit.