HMYOMAG-56K
MILLIPLEX® Human Myokine Magnetic Bead Panel
The Human Myokine Panel, using the Luminex xMAP technology, enables the simultaneous analysis of 15 myokine protein biomarkers in human serum, plasma and cell/tissue culture samples.
About This Item
Doporučené produkty
Quality Level
species reactivity
human
manufacturer/tradename
Milliplex®
assay range
accuracy: 100%
(Apelin)
accuracy: 92%
(IL-15)
accuracy: 96%
(FSTL-1)
accuracy: 97%
(LIF)
accuracy: 98%
(Oncostatin M (OSM))
sensitivity: 0.9 pg/mL
(MinDC+2SD; IL-6)
sensitivity: 14 pg/mL
(MinDC+2SD; FGF-21)
sensitivity: 259 pg/mL
(MinDC+2SD; Myostatin/GDF8)
sensitivity: 281 pg/mL
(MinDC+2SD; Irisin)
sensitivity: 4 pg/mL
(MinDC+2SD; LIF)
sensitivity: 40 pg/mL
(MinDC+2SD; Fractalkine/CX3CL1)
sensitivity: 5 pg/mL
(MinDC+2SD; IL-15)
sensitivity: 59 pg/mL
(MinDC+2SD; Osteocrin/Musclin)
sensitivity: 6 pg/mL
(MinDC+2SD; Oncostatin M (OSM))
sensitivity: 64 pg/mL
(MinDC+2SD; Apelin)
sensitivity: 7.5 ng/mL
(MinDC+2SD; Osteonectin (SPARC))
sensitivity: 737 pg/mL
(MinDC+2SD; Follistatin-like Protein 1 (FSTL1))
sensitivity: 815 pg/mL
(MinDC+2SD; Erythropoietin (EPO))
sensitivity: 9 pg/mL
(MinDC+2SD; BDNF)
sensitivity: 9.8 pg/mL
(MinDC+2SD; FABP3)
standard curve range: 0.6-2,400 pg/mL
(IL-6)
standard curve range: 10-40,000 pg/mL
(LIF)
standard curve range: 122-500,000 pg/mL
(Apelin)
standard curve range: 2-10,000 pg/mL
(BDNF)
standard curve range: 2-10,000 pg/mL
(IL-15)
standard curve range: 2-6,000 pg/mL
(Oncostatin M (OSM))
standard curve range: 24-100,000 pg/mL
(FABP3)
standard curve range: 244-1,000,000 pg/mL
(Erythropoietin (EPO))
standard curve range: 244-1,000,000 pg/mL
(Irisin)
standard curve range: 488-2,000,000 pg/mL
(Follistatin-like Protein 1 (FSTL1))
standard curve range: 488-2,000,000 pg/mL
(Myostatin/GDF8)
standard curve range: 49-200,000 pg/mL
(Fractalkine/CX3CL1)
standard curve range: 49-200,000 pg/mL
(Osteocrin/Musclin)
standard curve range: 5-20,000 pg/mL
(FGF-21)
standard curve range: 7-30,000 ng/mL
(Osteonectin (SPARC))
inter-assay cv: <15%
intra-assay cv: <10%
(Apelin)
inter-assay cv: <15%
intra-assay cv: <10%
(BDNF)
inter-assay cv: <15%
intra-assay cv: <10%
(Erythropoietin (EPO))
inter-assay cv: <15%
intra-assay cv: <10%
(FABP3)
inter-assay cv: <15%
intra-assay cv: <10%
(FGF-21)
inter-assay cv: <15%
intra-assay cv: <10%
(Follistatin-like Protein 1 (FSTL1))
inter-assay cv: <15%
intra-assay cv: <10%
(Fractalkine/CX3CL1)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-15)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-6)
inter-assay cv: <15%
intra-assay cv: <10%
(Irisin)
inter-assay cv: <15%
intra-assay cv: <10%
(LIF)
inter-assay cv: <15%
intra-assay cv: <10%
(Myostatin/GDF8)
inter-assay cv: <15%
intra-assay cv: <10%
(Oncostatin M (OSM))
inter-assay cv: <15%
intra-assay cv: <10%
(Osteocrin/Musclin)
inter-assay cv: <20%
intra-assay cv: <10%
(Osteonectin (SPARC))
technique(s)
multiplexing: suitable
detection method
fluorometric (Luminex xMAP)
shipped in
wet ice
General description
MILLIPLEX® Human Myokine Panel is a15-plex kit to be used for the simultaneous quantification of any or all of the following analytes in human serum,plasma and cell/tissue supernatant samples: Fractalkine/CX3CL1, BDNF, Oncostatin M (OSM), Osteonectin (SPARC), LIF, FGF-21, Erythropoietin (EPO), IL-15, IL-6, Apelin, Myostatin/GDF8, Irisin, Osteocrin/Musclin, FABP3 and Follistatin-Like Protein (FSTL 1). This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Metabolism
Application
- Analytes: Apelin (APLN), Brain-derived Neurotrophic Factor (BDNF), Erythropoeitin (EPO), Fatty Acid-Binding Protein 3 (FABP3), Fibroblast Growth Factor 21 (FGF21), Fractalkine (CX3CL1), Follistatin-Like 1 Protein (FSTL-1), IL-6, IL-15, Irisin, Leukemia Inhibitory Factor (LIF), Myostatin (MSTN/GDF8), Oncostatin M (OSM), Osteocrin (OSTN/Musclin), Osteonectin (SPARC)
- Recommended Sample Type: Human serum, plasma, and cell/tissue culture supernatants or lysates
- NOTE: Substantial amounts of BDNF are stored in circulating platelets and subsequently released upon platelet activation. Therefore, platelet-poor plasma is critical to ensure accurate measurement of circulating levels of BDNF.
- Recommended Sample Dilution: 25 μL per well of 1:2 diluted serum or plasma. Cell/tissue culture samples may be run neat or appropriately diluted in control media.
- Assay Run Time: Overnight (16-18 hours) at 2-8°C or 2 hours at room temperature (20-25°C)
- Research Category: Bone
- Research Subcategory: Metabolism
Features and Benefits
Other Notes
Legal Information
signalword
Danger
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT RE 2
target_organs
Respiratory Tract
Storage Class
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Osvědčení o analýze (COA)
Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Související obsah
Multiplex immunoassays like MILLIPLEX® Human Myokine Panel enable comprehensive myokine analysis, providing insights into related diseases.
Simplify protein biomarker discovery with the MILLIPLEX® PLEXpedition 115-Plex Multiplex Screening Panel. Effortlessly screen cytokines and other markers with Luminex® technology.
Multiplex immunoassays save time and sample volume in metabolic syndrome research, providing comprehensive insights into related conditions.
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.