1.19643
Superspher® 60 RP-select B (4 µm) HPLC Columns
HPLC sorbent
Synonyma:
TM=["LiChrospher"] C8 sorbent for HPLC
About This Item
Doporučené produkty
product name
Superspher® 60 RP-select B,
material
stainless steel column
agency
suitable for USP L7
product line
Superspher®
feature
endcapped: no
parameter
60 °C max. temp.
technique(s)
HPLC: suitable
mass spectrometry (MS): suitable (Low - Medium)
matrix
fully porous particle
matrix active group
C8 bonding phase
particle size
4 μm
pore size
60 Å pore size
operating pH range
2-7.5
bulk density
200‑400 kg/m3
separation technique
reversed phase
storage temp.
no temp limit
General description
Application
- Screening, library-assisted identification and validated quantification of 23 benzodiazepines, flumazenil, zaleplone, zolpidem and zopiclone in plasma by liquid chromatography/mass spectrometry with atmospheric pressure chemical ionization.: This study discusses a comprehensive method for the detection and quantification of various benzodiazepines in plasma using liquid chromatography/mass spectrometry, highlighting the utility of Superspher® 60 RP-select B columns in achieving high sensitivity and specificity (Kratzsch et al., 2004).
- Determination of heterocyclic aromatic amines in beef extract, cooked meat and rat urine by liquid chromatography with coulometric electrode array detection.: This research demonstrates the application of Superspher® 60 RP-select B in the precise measurement of heterocyclic aromatic amines in biological samples, emphasizing its role in enhancing detection sensitivity and accuracy (Gerbl et al., 2004).
- Screening, library-assisted identification and validated quantification of fifteen neuroleptics and three of their metabolites in plasma by liquid chromatography/mass spectrometry with atmospheric pressure chemical ionization.: This paper presents a validated method for detecting neuroleptics in plasma, utilizing Superspher® 60 RP-select B columns to achieve efficient separation and accurate quantification (Kratzsch et al., 2003).
- Validated assay for quantification of oxcarbazepine and its active dihydro metabolite 10-hydroxycarbazepine in plasma by atmospheric pressure chemical ionization liquid chromatography/mass spectrometry.: This study outlines a method for quantifying oxcarbazepine and its metabolite in plasma, using Superspher® 60 RP-select B columns to ensure high reproducibility and reliability in the assay (Maurer et al., 2002).
- Determination of the N-methyl-D-aspartate receptor NR2B subunit blocker Ro 63-1908 in rat, cynomolgus monkey and human plasma by high-performance liquid chromatography with column switching and fluorescence detection.: This research showcases the application of Superspher® 60 RP-select B in the sensitive and specific determination of NMDA receptor blockers in various biological matrices, enhancing analytical performance (Wyss et al., 2000).
Analysis Note
Pressure: ≤ 70 bar
Theoretical Plates (N/m) (1,2-Benzanthracene): ≥ 110000
Capacity factor (1,2-Benzanthracene): 3.5 - 5.0
stability testing (performance): passes test
MPPH/Diphenhydramine*HCL: 2.25 - 2.75
MPPH/Acetylsalicylic acid: 3.06 - 3.74
Toluene/MPPH: 2.37 - 2.63
capacity factor (Toluene): 11.05 - 14.95
Legal Information
Storage Class
11 - Combustible Solids
wgk_germany
nwg
flash_point_f
Not applicable
flash_point_c
Not applicable
Osvědčení o analýze (COA)