Přejít k obsahu
Merck
Všechny fotografie(1)

Key Documents

1.11787

Supelco

Potassium hydroxide solution

c(KOH) = 2.0 mol/l (2 N) in methanol, ready-to-use volumetric solution for titration in non-aqueous media, Titriplex®

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

UNSPSC Code:
12352305
NACRES:
NA.21

product name

Potassium hydroxide solutionin methanol, c(KOH) = 2.0 mol/l (2 N), Titripur®

Quality Level

product line

Titripur®

form

liquid

autoignition temp.

455 °C (Methanol)

quality

Analyzed in our ISO 17025 accredited QC lab

expl. lim.

5.5-44 % (v/v) Methanol)

reaction suitability

reaction type: Acid-base reactions

concentration

0.1 M

technique(s)

titration: suitable

pH

14 (20 °C in H2O)

transition temp

flash point 7 °C

density

0.93 g/cm3 at 20 °C

storage temp.

15-25°C

Features and Benefits

Accreditation:
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.

Analysis Note

Form liquid
Amount-of-substance concentration 1.990 - 2.010 mol/L
Measurement uncertainty ± 0.006 mol/L
Traceability NIST SRM

The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 84 potassium hydrogen phthalate) by means of volumetric standard potassium hydrogen phthalate (article number 1.02400), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.

Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.

Legal Information

Titripur is a registered trademark of Merck KGaA, Darmstadt, Germany

signalword

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Eye Dam. 1 - Flam. Liq. 2 - Met. Corr. 1 - Skin Corr. 1A - STOT SE 1

Storage Class

3 - Flammable liquids

wgk_germany

WGK 2

flash_point_f

44.6 °F

flash_point_c

7 °C


Seznamy omezení vyplývajících z předpisů

Seznamy omezení vyplývajících z předpisů jsou poskytovány zejména pro chemické produkty. Pro jiné než chemické produkty lze poskytovat pouze omezené informace. Žádný záznam znamená, že v seznamech není obsažena žádná ze součástí. Povinností uživatele je zajistit bezpečné a zákonné použití produktu.

EU REACH Annex XVII (Restriction List)

CAS No.

Osvědčení o analýze (COA)

Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis.