Vybrat velikost
13 300,00 Kč
17 700,00 Kč
43 100,00 Kč
13 300,00 Kč
O této položce
Přeskočit na
Název produktu
Hydrochloric acid solution, 30% Ultrapur
SMILES string
Cl
InChI
1S/ClH/h1H
InChI key
VEXZGXHMUGYJMC-UHFFFAOYSA-N
agency
suitable for EPA 200.7, suitable for EPA 200.8
vapor pressure
21.8 hPa ( 20 °C)
description
for inorganic trace analysis
assay
30%
form
liquid
pH
<1 (20 °C, 300 g/L in H2O)
bp
85 °C/1013 hPa
mp
-50 °C
Quality Level
solubility
water: soluble
density
1.15 g/cm3 at 20 °C
storage temp.
2-30°C
Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů
Související kategorie
1 of 4
Tato položka | |||
|---|---|---|---|
| grade for inorganic trace analysis | grade for inorganic trace analysis | grade - | grade - |
| assay 30% | assay 30% | assay ≥32% (alkalimetric) | assay ≥32.0% (alkalimetric) |
| Quality Level 100 | Quality Level 100 | Quality Level 200 | Quality Level 300 |
| agency suitable for EPA 200.7, suitable for EPA 200.8 | agency suitable for EPA 200.7, suitable for EPA 200.8 | agency - | agency - |
| form liquid | form liquid | form liquid | form liquid |
| storage temp. 2-30°C | storage temp. 15-25°C | storage temp. 15-25°C | storage temp. 15-25°C |
Application
- Corrosion inhibition of mild steel in hydrochloric acid solution by the expired Ampicillin drug.: This study investigates the use of expired Ampicillin as a corrosion inhibitor for mild steel in hydrochloric acid solutions, showcasing an innovative approach to repurposing pharmaceutical waste (Alamry et al., 2023).
- Determination of Carcinogenic Primary Aromatic Amines Contained as Impurities in Synthetic Organic Colorants.: This research presents a method for detecting carcinogenic primary aromatic amines in synthetic organic colorants using hydrochloric acid solutions for sample preparation, contributing to enhanced safety in consumer products (Kawakami et al., 2022).
- Determination of Amino Acid Composition of Ganirelix Acetate in an Injectable Formulation by Pre-column Derivatization with 6-Aminoquinolyl-N-hydroxysuccinimidyl Carbamate.: This study describes the determination of amino acids in Ganirelix Acetate formulations using hydrochloric acid solutions, providing a detailed analytical method for pharmaceutical applications (Ummiti and Kumar, 2020).
- In-process prepared deep eutectic solvent based homogeneous liquid-liquid microextraction for the determination of irgaphos 168 and irganox 1010 in polypropylene packed drinks.: The research focuses on using hydrochloric acid solutions in the extraction process for determining antioxidants in drinks, enhancing food safety and quality control methods (Naebi et al., 2020).
signalword
Danger
hcodes
Hazard Classifications
Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1B - STOT SE 3
target_organs
Respiratory system
Skladovací třída
8B - Non-combustible corrosive hazardous materials
wgk
WGK 1
flash_point_f
Not applicable
flash_point_c
Not applicable
Osvědčení o analýze (COA)
Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Související obsah
This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.
Techniky atomové spektroskopie, jako jsou AAS, AES, ICP-OES a ICP-MS, určují a kvantifikují prvkové složení vzorků.
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis