Vybrat velikost
1 640,00 Kč
1 640,00 Kč
O této položce
Přeskočit na
Název produktu
Chlorine reagent Cl2-1 (liquid), photometric, 0.010 - 6.00 mg/l Cl2 for free chlorine: Cl2-1 and Cl2-2, for total chlorine: Cl2-1, Cl2-2, and Cl2-3 Spectroquant®
form
liquid
usage
sufficient for 200 tests
specific analyte(s)
chlorine
measuring range
0.010-6.00 mg/L (Cl2)
technique(s)
photometry: suitable
density
1.25 g/cm3 at 20 °C
application(s)
aquaculture
boiler and cooling water
disinfection control
drinking water
ground and surface water
swimming pools
wastewater
compatibility
for use with Spectroquant® Move 100
for use with Spectroquant® Move DC
for use with Spectroquant® Nova 60 A
for use with Spectroquant® Prove 100 (plus)
for use with Spectroquant® Prove 300 (plus)
for use with Spectroquant® Prove 600 (plus)
detection method
photometric (DPD)
storage temp.
15-25°C
Quality Level
1 of 4
Tato položka | 1.00087 | 1.00088 | 1.11114 |
|---|---|---|---|
| detection method photometric (DPD) | detection method photometric (DPD) | detection method photometric (DPD) | detection method colorimetric |
| specific analyte(s) chlorine | specific analyte(s) chlorine | specific analyte(s) chlorine | specific analyte(s) chlorine |
| technique(s) photometry: suitable | technique(s) photometry: suitable | technique(s) photometry: suitable | technique(s) - |
| measuring range 0.010-6.00 mg/L (Cl2) | measuring range 0.010-6.00 mg/L (Cl2) | measuring range 0.010-6.00 mg/L (Cl2) | measuring range - |
| compatibility for use with Spectroquant® Move 100, for use with Spectroquant® Nova 60 A, for use with Spectroquant® Prove 300, for use with Spectroquant® Move DC, for use with Spectroquant® Prove 600, for use with Spectroquant® Prove 100 | compatibility for use with Spectroquant® Move 100, for use with Spectroquant® Move DC, for use with Spectroquant® Nova 60 A, for use with Spectroquant® Prove 100, for use with Spectroquant® Prove 300, for use with Spectroquant® Prove 600 | compatibility for use with Spectroquant® Move 100, for use with Spectroquant® Move DC, for use with Spectroquant® Nova 60 A, for use with Spectroquant® Prove 100, for use with Spectroquant® Prove 300, for use with Spectroquant® Prove 600 | compatibility - |
| form liquid | form liquid | form liquid | form - |
General description
Reagents 1.00087, 1.00088 (only for the determination of total chlorine) and the equipment 1.00089. More information can be found in the instruction leaflet.
Legal Information
Skladovací třída
12 - Non Combustible Liquids
wgk
WGK 1
flash_point_f
Not applicable
flash_point_c
Not applicable
Osvědčení o analýze (COA)
Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Protokoly
Preparation of a standard solution for free Chlorine according to DIN EN ISO 7393
Preparation of a standard solution for total chlorine.
AQA Standard for free chlorine - Preparation of a standard solution for free chlorine
Související obsah
Řešení pro kontrolu dezinfekce zajišťují bezpečnost potravin a dodržování předpisů při výrobě potravin a nápojů.
Disinfection control solutions ensure food safety and regulatory compliance in food & beverage manufacturing.
Active Filters
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis