Z561711
PlasmaFlo gas flow mixer and pressure monitor
AC/DC input 230 V AC
Synonyma:
Flow Mixer
Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen
About This Item
Doporučené produkty
feature
CE compliant
H × W × D
8.5 in. × 10 in. × 8 in.
8.5 in. × 10 in. × 8 in.
weight
12 lb
Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů
Související kategorie
General description
The PlasmaFlo may be used with the High Power Expanded, Expanded, or Basic Plasma Cleaner (230V) and is beneficial for gas mixing, more precise quantitative control of the gas flowrate and monitoring of vacuum pressure.
* Maximum flowrate varies with process gas and regulated pressure. Correlated flowrate tables are available for the most common process gases (Air, Ar, N2, O2) used with our Plasma Cleaners and metered at 10 psig. Flowrate tables for other process gases and regulated pressures can be made available. Please inquire with Harrick Plasma.
- Dual gas inputs into flowmeters with 49 mL/min maximum flowrate* and ±2% accuracy
- Thermocouple vacuum gauge and digital meter (1 to 1999 mTorr)
- Inputs/Output connection: ¼ in. Swagelok to ¼ in. O.D. stainless steel hose adaptor
* Maximum flowrate varies with process gas and regulated pressure. Correlated flowrate tables are available for the most common process gases (Air, Ar, N2, O2) used with our Plasma Cleaners and metered at 10 psig. Flowrate tables for other process gases and regulated pressures can be made available. Please inquire with Harrick Plasma.
Use with the Expanded or Basic Plasma Cleaner for fine control of up to 2 process gases, process gas mixing, and monitoring of chamber pressure.
* Maximum flowrate varies with process gas and regulated pressure. Correlated flowrate tables are available for the most common process gases (Air, Ar, N2, O2) used with our Plasma Cleaners and metered at 10 psig. Flowrate tables for other process gases and regulated pressures can be made available.
- Dual gas inputs
- Flowmeter 1: 49 mL/min maximum flowrate *
- Flowmeter 2: 104 mL/min maximum flowrate *
- ±2% accuracy
- Thermocouple vacuum gauge and digital meter (1 to 1999 mTorr)
- Input/Output connection: 1/4 in. Swagelok to 1/4 in. O.D. stainless steel hose adapter
* Maximum flowrate varies with process gas and regulated pressure. Correlated flowrate tables are available for the most common process gases (Air, Ar, N2, O2) used with our Plasma Cleaners and metered at 10 psig. Flowrate tables for other process gases and regulated pressures can be made available.
Osvědčení o analýze (COA)
Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.