Přejít k obsahu
Merck
Všechny fotografie(2)

Hlavní dokumenty

444464

Sigma-Aldrich

Polyanetholesulfonic acid sodium salt

Synonyma:

Sodium polyanetholesulfonate

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

Číslo CAS:
MDL number:
UNSPSC Code:
12162002
NACRES:
NA.23

form

powder

mol wt

average Mv 9,000-11,000

SMILES string

C/C=C/C1=CC=C(C=C1)OC.[O-]S(=O)[O-].[Na+]

InChI

1S/C10H12O.Na.H2O3S/c1-3-4-9-5-7-10(11-2)8-6-9;;1-4(2)3/h3-8H,1-2H3;;(H2,1,2,3)/q;+1;/p-2/b4-3+;;

InChI key

JKJBFNAERWARKW-CZEFNJPISA-L

Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů

General description

Canonical SMILES: CC=CC1=CC=C(C=C1)OC.[O-]S(=O)[O-].[Na+]

Application

Anticoagulant

pictograms

Exclamation mark

signalword

Warning

Hazard Classifications

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

target_organs

Respiratory system

Storage Class

11 - Combustible Solids

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable


Vyberte jednu z posledních verzí:

Osvědčení o analýze (COA)

Lot/Batch Number

Nevidíte správnou verzi?

Potřebujete-li konkrétní verzi, můžete vyhledat daný certifikát podle čísla dávky nebo čísla šarže.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

J Cerda et al.
British journal of experimental pathology, 67(5), 623-628 (1986-10-01)
Levels of plasma fibronectin (Fn) were 63% lower than normal 15 min after the intravenous injection of liquoid (P less than 0.01); 3 h later they were still low but rebounded to 35% above normal (P less than 0.01) by
E R Schnur et al.
Journal of clinical microbiology, 27(4), 654-656 (1989-04-01)
During an 8-month period at Children's Hospital, Oakland, Calif., a 9% rate for positive blood culture for children with Neisseria meningitidis meningitis was identified. The blood culture system used in each case was the BACTEC NR 730. This rate seemed
B L Wasilauskas et al.
Journal of clinical microbiology, 35(3), 588-590 (1997-03-01)
We previously reported an inhibitory effect on Mycobacterium avium-M. intracellulare (MAI) when blood collected and processed with the Isolator system was placed in BACTEC 12B bottles for radiometric monitoring. We sought to identify the specific component(s) of the Isolator lysis-anticoagulant
C Gamazo et al.
Journal of clinical microbiology, 31(12), 3200-3203 (1993-12-01)
The detection of Brucella bacteremia by subculture does not always correlate with a positive signal in the BACTEC NR730 nonradiometric system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.). The effect of the inoculum size, pH, sodium polyanetholesulfonate, carbon sources (i-erythritol
Kerry Varettas et al.
Journal of clinical microbiology, 43(9), 4613-4615 (2005-09-08)
The tube coagulase test (TCT) performed directly from positive blood culture bottles has been used to reduce the turnaround time for identifying Staphylococcus aureus. Most reports have shown the test to be specific but often lacking sufficient sensitivity to be

Sortimentní položky

Recently, layer-by-layer (LbL) assembly has emerged as a versatile, gentle and, simple method for immobilization of functional molecules in an easily controllable thin film morphology.1,2 In this short review, we introduce recent advances in functional systems fabricated by using the mild, yet adaptable LbL technique.

We present an article that discusses two applications in particular; first, using these layers as polyelectrolyte membranes to control permeability.

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis.