Saltar al contenido
Merck

M5655

Sigma-Aldrich

Azul de tiazolil Bromuro de tetrazolio

powder, BioReagent, suitable for cell culture, suitable for insect cell culture, ≥97.5% (HPLC)

Sinónimos:

Bromuro de 3-(4,5-dimetil-2-tiazolil)-2,5-difenil-2H-tetrazolio, Bromuro de metiltiazolildifenil-tetrazolio, MTT

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula empírica (notación de Hill):
C18H16BrN5S
Número de CAS:
Peso molecular:
414.32
Beilstein/REAXYS Number:
4081397
EC Number:
MDL number:
UNSPSC Code:
12352207
PubChem Substance ID:
NACRES:
NA.75
En este momento no podemos mostrarle ni los precios ni la disponibilidad

product line

BioReagent

Quality Level

assay

≥97.5% (HPLC)

form

powder

technique(s)

cell culture | insect: suitable
cell culture | mammalian: suitable

mp

195 °C (dec.) (lit.)

solubility

H2O: 5 mg/mL

storage temp.

2-8°C

SMILES string

[Br-].Cc1nc(sc1C)-[n+]2nc(nn2-c3ccccc3)-c4ccccc4

InChI

1S/C18H16N5S.BrH/c1-13-14(2)24-18(19-13)23-21-17(15-9-5-3-6-10-15)20-22(23)16-11-7-4-8-12-16;/h3-12H,1-2H3;1H/q+1;/p-1

InChI key

AZKSAVLVSZKNRD-UHFFFAOYSA-M

¿Está buscando productos similares? Visita Guía de comparación de productos

Application

El azul de tiazolil Azul tetrazolio (MTT) puede utilizarse para medir la proliferación celular. El MTT produce una disolución amarillenta que vira a formazano de MTT azul violeta insoluble en agua por acción de las deshidrogenasas mitocondriales de las células vivas. Los cristales azules se solubilizan con isopropanol acidificado y la intensidad se mide colorimétricamente a 570 nm.
El azul de tiazolil Azul tetrazolio (MTT) puede utilizarse para medir la proliferación celular. El MTT produce una disolución amarillenta que vira a formazano de MTT azul violeta insoluble en agua por acción de las deshidrogenasas mitocondriales de las células vivas. Los cristales azules se solubilizan con isopropanol acidificado y la intensidad se mide colorimétricamente a 570 nm. El MTT se ha utilizado como un reactivo histoquímico o citoquímico y para la detección del NAD. Los sistemas enzimáticos ligados a ADP de los tejidos no pueden detectarse con MTT, debido a la unión del catión por la trampa de cianuro utilizada. El MTT se reduce rápidamente al formazano, que forma complejos con el níquel, el cobre y el cobalto; los quelatos de cobalto se han utilizado en los sistemas oxidativos.
El bromuro de tetrazolio de azul de tiazolilo se ha utilizado como indicador colorimétrico de la actividad metabólica en análisis de viabilidad celular (análisis MTT).[1][2][3][4] Se ha utilizado también para determinar la proliferación celular.[5]

related product

Referencia del producto
Descripción
Precios

pictograms

Health hazardExclamation mark

signalword

Warning

Hazard Classifications

Eye Irrit. 2 - Muta. 2 - Skin Irrit. 2 - STOT SE 3

target_organs

Respiratory system

Storage Class

11 - Combustible Solids

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Dasatinib synergizes with doxorubicin to block growth, migration, and invasion of breast cancer cells
Pichot CS, et al.
British Journal of Cancer, 101(1), 38-38 (2009)
UNC569, a novel small-molecule mer inhibitor with efficacy against acute lymphoblastic leukemia in vitro and in vivo
Christoph S, et al.
Molecular Cancer Therapeutics (2013)
Nanoparticles made from novel starch derivatives for transdermal drug delivery
Santander Ortega MJ, et al.
Journal of Controlled Release : Official Journal of the Controlled Release Society, 141(1), 85-92 (2010)
Sahar Yarahmadi et al.
Gene, 711, 143939-143939 (2019-06-21)
Sirtuin 1 is one of the regulators of cell growth and survival and its inhibition is suggested as a suitable mechanism to overcome breast cancer development. In this study we explored the role of miR-211-5p in SIRT1/p53 pathway and its
Fabrication, mechanical properties, and biocompatibility of graphene-reinforced chitosan composites
Fan H, et al.
Biomacromolecules, 11(9), 2345-2351 (2010)

Questions

1–10 of 10 Questions  
  1. Should I prepare fresh for each use or I directly resuspend in 20 ml of water (for the 100 mg bottle) and store? In the latter case, how can I store the solution?

    1 answer
    1. The solution may be filtered through a 0.2 μm filter and stored at 2-8°C for frequent use or stored in aliquots and frozen at -20°C for extended periods.

      Helpful?

  2. What's the difference between M5655 and M2003?

    1 answer
    1. Product M5655 is Thiazolyl Blue Tetrazolium Bromide and Product M2003 is Thiazolyl blue formazan.

      MTT (Cat. no. M5655) is used in the measurement of cell proliferation. MTT produces a yellowish solution that is converted to dark blue, water-insoluble MTT formazan (Product M2003) by mitochondrial dehydrogenases of living cells. The blue MTT formazan crystals are solubilized with acidified isopropanol and the intensity is measured colorimetrically at 570 nm. Thus, the amount of blue formazan is proportional to the number of viable cells. For more information regarding this particular assay, we do offer an assay kit, TOX1, which is based on this principle: https://www.sigmaaldrich.com/product/sigma/tox1.

      Helpful?

  3. What type of multi-well plate should be used for the Thiazolyl Blue Tetrazolium Bromide (MTT) assay?

    1 answer
    1. It is recommended that flat bottom multi-well plates be used for the MTT assay. The use of tissue culture treated plates is only important if necessary for good cell growth.  If cells are grown in larger plates, the supernatant after cell lysis can be transferred to a 96 well plate for reading.

      Helpful?

  4. Is the MTT assay quantitative?

    1 answer
    1. The MTT asay is a method to assess cell viability.  This assay is a semiquantitative assay. The assay is used to compare the viability changes in treated cells to untreated cells. The absorbance is indicative of the cell number. The higher the absorbance, the greater the number of viable cells present. Most researchers compare the absorbance of the two samples as a ratio (ABS treated cells/ABS untreated cells) to get a fold increase/decrease in cell number.

      Helpful?

  5. How can I store solutions of Thiazolyl Blue Tetrazolium Bromide (MTT)?

    1 answer
    1. Reconstituted MTT solution is stable for at least 6 months when stored frozen (-20 °C). Storage of reconstituted MTT solution at 2-8°C for more than 2 weeks may cause decomposition and yield erroneous results.

      Helpful?

  6. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  7. What can be used to make a solution of Thiazolyl Blue Tetrazolium Bromide (MTT)?

    1 answer
    1. We test the solubility of MTT in water at a concentration of 5 mg/mL.  For the MTT viability assay, we dissolve Product No. M5655 at a concentration of 5 mg/ml in RPMI-1640 without phenol red. This medium is available as a powder (Product No.R8755) or liquid (Product No. R7509). MTT can be solubilized in any culture media or balanced salt solution that does not contain phenol red as a pH indicator.

      Helpful?

  8. Why is a reference wavelength used for data analysis of Thiazolyl Blue Tetrazolium Bromide (MTT)?

    1 answer
    1. The reference wavelength (630-690 nm) is used to adjust for the optical variation in the wells of the plate.  It also corrects for dust and fingerprints that can be present.  The assay is read at 570 nm.  The reference wavelength needs to be far enough away from the assay wavelength so as not to affect those values.

      Helpful?

  9. How can Thiazolyl Blue Tetrazolium Bromide be used for staining dehydrogenase in tissue sections?

    1 answer
    1. Products M2128 or M5655, Thiazolyl Blue Tetrazolium Bromide can be used for staining dehydrogenase in tissue sections. See the method below. Reagent PreparationMTT (2 mg/ml distilled water) 2.5 ml0.2 M Tris buffer, pH 7.4 2.5 ml0.5 M cobalt chloride 0.5 ml0.05 M magnesium chloride 1.0 mlDistilled water 2.5 mlThe pH of this solution is adjusted to 7.0 if necessary. Aliquot and store at -20°C until required. Sample PreparationCut cytostat sections at 5 to 7 microns. Do not fix. Method:1. Incubate sections in appropriate incubation solution at 37°C for 30-60 minutes.2. Transfer sections to 15% formol saline, 15 minutes.3. Wash in distilled water4. Counterstain in 2% methyl green if required.5. Wash in distilled water.6. Mount in glycerin Jelly. ResultsEnzyme: Black formazan deposits with MTT Source:  Bancroft and Gamble, Theory and Practice of Histological Techniques, Fifth Edition. Churchill Livingstone, London, 2002, page 610.

      Helpful?

  10. What can be used to solubilize MTT formazan (the product of the Thiazolyl Blue Tetrazolium Bromide - MTT reaction)?

    1 answer
    1. Mitochondrial dehydrogenases of viable cells cleave the tetrazolium ring of the MTT, yielding purple MTT formazan crystals. These crystals are not soluble in aqueous solutions; they may be dissolved in acidified isopropanol (0.1 N HCl in anhydrous isopropanol). If this does not lyse the cells, Triton X-100 can be added to the acidified isopropanol. A typical working concentration is 10% Triton X-100 (i.e., 1 volume of 100% Triton X-100 + 9 volumes of acidified isopropanol).

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico