Saltar al contenido
Merck
Todas las fotos(1)

Documentos clave

D9905

Sigma-Aldrich

Denhardt′s Solution

for Northern and Southern blotting, lyophilized powder

Sinónimos:

Denhardt′s Solution For Blotting Technique

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
12161700
NACRES:
NA.25

grado

for molecular biology

Nivel de calidad

Formulario

lyophilized powder

técnicas

Southern blotting: suitable

actividad extraña

DNAses, RNases, NICKases, endonucleases, and exonucleases, none detected

temp. de almacenamiento

2-8°C

Descripción general

Denhardt′s Solution is a blocking agent routinely used to reduce non-specific binding of detection reagents to the Northern and Southern Blot membranes. This powder can be used to make a 50x concentrate that can be diluted to any concentration for use in a variety of pre-hybridization and hybridization buffers.

Aplicación

Denhardt′s Solution has been used:
  • as a component in hybridization buffer for the hybridization of brain sections
  • in in-situ hybridization peroxidase-(antiperoxidase method-whole mounts) (ISHPAP-WM) process
  • in the preparation of hybridization mixture

Suitable as a blocking Buffer for Southern and Northern blot membranes.

Acciones bioquímicas o fisiológicas

Denhardt′s solution and gelatin-chrome alum can be used to treat chromosomes for G-banding with trypsin after in situ hybridization.

Componentes

Each vial of Denhardt′s powder contains 50mg Bovine Serum Albumin (BSA), 50mg Ficoll, and 50mg Polyvinylpyrrolidone (PVP).

Nota de preparación

To make a 50x concentrate, dissolve entire contents of vial in 5 mL molecular biology grade water. Store at -20°C for up to two years.

Código de clase de almacenamiento

11 - Combustible Solids

Clase de riesgo para el agua (WGK)

WGK 3

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable

Equipo de protección personal

Eyeshields, Gloves, type N95 (US)


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Sambrook, J., et al.
Molecular Cloning: A Laboratory Manual, 9-9 (1989)
Kazuya Morikawa et al.
PLoS pathogens, 8(11), e1003003-e1003003 (2012-11-08)
It has long been a question whether Staphylococcus aureus, a major human pathogen, is able to develop natural competence for transformation by DNA. We previously showed that a novel staphylococcal secondary sigma factor, SigH, was a likely key component for
Andreas Toegl et al.
Journal of biomolecular techniques : JBT, 14(3), 197-204 (2003-09-19)
Protein and DNA microarrays have become a standard tool in proteomics/genomics research. In order to guarantee fast and reproducible hybridization results, the diffusion limit must be overcome. Surface acoustic wave (SAW) micro-agitation chips efficiently agitate the smallest sample volumes (down
M A Hull et al.
Gut, 43(4), 525-536 (1998-11-21)
Basic fibroblast growth factor (bFGF) promotes angiogenesis and healing of gastric ulcers in rats, and bFGF expression is up regulated in such ulcers. However, little is known about expression of bFGF in human gastric mucosa. To investigate bFGF expression in
E J Mackie et al.
Journal of cell science, 103 ( Pt 3), 765-771 (1992-11-01)
The extracellular matrix glycoprotein, tenascin, is associated in vivo with mesenchyme undergoing osteogenesis and chondrogenesis, but is absent from mature bone and cartilage matrix. The expression of tenascin by osteoblastic cells in vitro has been investigated by immunoblotting and immunocytochemistry.

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico