Saltar al contenido
Merck

C0742

Sigma-Aldrich

CKI-7 dihydrochloride

≥98% (HPLC), solid, CK1 inhibitor

Sinónimos:

N-(2-Aminoethyl)-5-chloroisoquinoline-8-sulphonamide dihydrochloride

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula empírica (notación de Hill):
C11H12ClN3O2S · 2HCl
Número de CAS:
Peso molecular:
358.67
Número MDL:
Código UNSPSC:
12352200
ID de la sustancia en PubChem:
NACRES:
NA.77

Nombre del producto

CKI-7 dihydrochloride, ≥98% (HPLC), solid

Nivel de calidad

Ensayo

≥98% (HPLC)

Formulario

solid

condiciones de almacenamiento

desiccated

color

white to light tan

solubilidad

H2O: >5 mg/mL

temp. de almacenamiento

−20°C

cadena SMILES

Cl[H].Cl[H].NCCNS(=O)(=O)c1ccc(Cl)c2ccncc12

InChI

1S/C11H12ClN3O2S.2ClH/c12-10-1-2-11(18(16,17)15-6-4-13)9-7-14-5-3-8(9)10;;/h1-3,5,7,15H,4,6,13H2;2*1H

Clave InChI

JUAVTXYOCISSSL-UHFFFAOYSA-N

Acciones bioquímicas o fisiológicas

CKI-7 is a CK1 inhibitor; also inhibits SGK, S6K1 and MSK1.
CKI-7 is a CK1 inhibitor; also inhibits SGK, S6K1 and MSK1. CKI-7 inhibits SGK as potently as CK1. IC50 = 6 μM.

Precaución

Material is hygroscopic

Pictogramas

Skull and crossbones

Palabra de señalización

Danger

Frases de peligro

Clasificaciones de peligro

Acute Tox. 3 Oral

Código de clase de almacenamiento

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

Clase de riesgo para el agua (WGK)

WGK 3

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable

Equipo de protección personal

Eyeshields, Faceshields, Gloves, type P2 (EN 143) respirator cartridges


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Masaharu Hata et al.
Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al], 190(10), 899-904 (2014-03-14)
Wide surgical excision is the standard treatment for angiosarcoma of the scalp, but many patients are inoperable. Therefore, we investigated the outcome of radiation therapy for angiosarcoma of the scalp. Seventeen patients with angiosarcoma of the scalp underwent radiation therapy
Hanna K Gaggin et al.
JACC. Heart failure, 2(1), 65-72 (2014-03-14)
This analysis aimed to perform a head-to-head comparison of 3 of the promising biomarkers of cardiovascular (CV) outcomes in heart failure (HF)-soluble ST2 (sST2), growth differentiation factor (GDF)-15, and highly-sensitive troponin T (hsTnT)-and to evaluate the role of serial measurement
Sandra Krohn et al.
Journal of clinical microbiology, 52(5), 1754-1757 (2014-03-14)
Qualitative and quantitative 16S rRNA gene-based real-time PCR and direct sequencing were applied for rapid detection and identification of bacterial DNA (bactDNA) in 356 ascites samples. bactDNA was detected in 35% of samples, with a mean of 3.24 log copies
Xueyuan Guo et al.
Chinese medical journal, 127(6), 1033-1038 (2014-03-14)
Neutrophil/lymphocyte ratio (NLR) has been proposed as a novel marker of systemic inflammation and oxidative stress. The objective of this study was to ascertain the relationship between levels of NLR and recurrence of lone atrial fibrillation (AF) after catheter ablation.
Subodh Verma et al.
The lancet. Diabetes & endocrinology, 1(4), 317-328 (2014-03-14)
The choice between coronary artery bypass surgery (CABG) and percutaneous coronary intervention (PCI) for revascularisation in patients with diabetes and multivessel coronary artery disease, who account for 25% of revascularisation procedures, is much debated. We aimed to assess whether all-cause

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico