Saltar al contenido
Merck
  • Development and validation of an ultra high performance liquid chromatography tandem mass spectrometry method for simultaneous determination of sulfonamides, quinolones and benzimidazoles in bovine milk.

Development and validation of an ultra high performance liquid chromatography tandem mass spectrometry method for simultaneous determination of sulfonamides, quinolones and benzimidazoles in bovine milk.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-06-03)
Xiao-Lin Hou, Guo Chen, Li Zhu, Ting Yang, Jian Zhao, Lei Wang, Yin-Liang Wu
RESUMEN

A simple, sensitive and reliable analytical method was developed for the simultaneous determination of 38 veterinary drugs (18 sulfonamides, 11 quinolones and 9 benzimidazoles) and 8 metabolites of benzimidazoles in bovine milk by ultra high performance liquid chromatography-positive electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS). Samples were extracted with acidified acetonitrile, cleaned up with Oasis(®) MCX cartridges, and analyzed by LC-MS/MS on an Acquity UPLC(®) BEH C18 column with gradient elution. The method allows such multi-analyte measurements within a 13min runtime while the specificity is ensured through the MRM acquisition mode. The method was validated according to the European Commission Decision 2002/657/EC determining specificity, decision limit (CCα), detection capability (CCβ), recovery, precision, linearity and stability. For compounds which have MRLs in bovine milk, the CCα values fall into a range from 11 to 115μg/kg, and the CCβ values fall within a range of 12-125μg/kg. For compounds which have not MRLs in bovine milk, the CCα values fall into a range from 0.01 to 0.08μg/kg, and the CCβ values fall within a range of 0.02-0.11μg/kg. The mean recoveries of the 46 analytes were between 87 and 119%. The calculated RSD values of repeatability and within-laboratory reproducibility experiments were below 11% and 15% for the 46 compounds, respectively. The method was demonstrated to be suitable for the simultaneous determination of sulfonamides, quinolones and benzimidazoles in bovine milk.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Hidróxido de amonio solution, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
Acetonitrilo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Ácido fórmico, reagent grade, ≥95%
Sigma-Aldrich
Metanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Ácido fórmico, ACS reagent, ≥96%
Sigma-Aldrich
Ammonium acetate, ACS reagent, ≥97%
Sigma-Aldrich
Ácido fórmico, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
Acetonitrilo, ACS reagent, ≥99.5%
Sigma-Aldrich
Hidróxido de amonio solution, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
Acetonitrilo, anhydrous, 99.8%
Sigma-Aldrich
Ammonium acetate, ≥99.99% trace metals basis
Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Metanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Metanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Ácido fórmico, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
Hidróxido de amonio solution, puriss., 30-33% NH3 in H2O
Sigma-Aldrich
Ácido fórmico, ACS reagent, ≥88%
Sigma-Aldrich
Metanol, Absolute - Acetone free
Sigma-Aldrich
Metanol, anhydrous, 99.8%
Sigma-Aldrich
Ammonium acetate, for molecular biology, ≥98%
Sigma-Aldrich
Metanol, BioReagent, ≥99.93%
Sigma-Aldrich
Metanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Hidróxido de amonio solution, puriss. p.a., reag. ISO, reag. Ph. Eur., ~25% NH3 basis
Sigma-Aldrich
Ammonium acetate solution, for molecular biology, 7.5 M
Sigma-Aldrich
Acetonitrilo, suitable for HPLC-GC, ≥99.8% (GC)