Saltar al contenido
Merck
Todas las fotos(2)

Documentos clave

S2HVU05RE

Millipore

Sistema de filtración al vacío Millipore® Stericup® Quick Release

pore size 0.45 μm, PVDF membrane, funnel capacity 500 mL, pack of 12 ea

Sinónimos:

SCHVU05RE, Sistema de filtración al vacío estéril Stericup Quick Release-HV

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
41104914
eCl@ss:
32031623
NACRES:
NB.24
En este momento no podemos mostrarle ni los precios ni la disponibilidad

Materiales

PVDF membrane
polystyrene bottle
polystyrene funnel(s)
polystyrene housing

Nivel de calidad

esterilidad

sterile; irradiated

Línea del producto

Stericup®

Características

hydrophilic

envase

pack of 12 ea

Parámetros

45 °C max. temp.

descripción

2.4 mL (hold-up volume)

técnicas

sterile filtration: suitable

Altura

263 mm

capacidad

500 mL

Diámetro

12.5 cm

diám. del filtro

73 mm

filtración área

40 cm2

embudo capacidad

500 mL

Matriz

Durapore®

tamaño de poro

0.45 μm pore size

Adaptador

inlet funnel
outlet flask (Receiver)

Condiciones de envío

ambient

Descripción general

Este artículo es un sustituto directo de SCHVU05RE
Trabaje con facilidad y filtre con confianza con los sistemas de filtración Stericup® y Steritop® .

Las unidades de esterilización mediante filtración al vacío Stericup® y Steritop® utilizan membranas de gran rendimiento para la esterilización óptima mediante filtración de los reactivos de laboratorio, los amortiguadores y los medios. Estos dispositivos combinan caudales y rendimiento superiores con baja adsorción inespecífica y un diseño sin punta estable.

Esta unidad de filtración con membrana de fluoruro de polivinilideno (PVDF) y tamaño de poro de 0,45 μm Stericup® combina una tapa de botella de 500 ml con un matraz receptor de 500 ml y una tapa para el procesamiento y el almacenamiento.

Aplicación

Los sistemas Stericup® y Steritop® están diseñados para reducir la formación de espuma y la desnaturalización de las proteínas mientras maximizan el flujo y pueden utilizarse para la filtración al vacío esterilizante de disoluciones acuosas como medios de cultivo de tejidos y líquidos biológicos.

  • Medios de cultivo de tejidos +/- aditivos
  • Amortiguadores
  • Disoluciones biológicas
Para uso exclusivo en investigación

Características y beneficios

  • El embudo de filtración Quick Release se desconecta de la botella receptora con solo un un cuarto de vuelta—, lo que reduce la probabilidad de derrame y facilita la manipulación en la mesa de trabajo o debajo de la campana.
  • La identificación del producto en negrita en el embudo de filtración Steritop® muestra claramente las características de la membrana, como su composición y el tamaño de los poros, para una selección de productos rápida y apropiada para la aplicación.
  • El tapón de cierre mediante un clic está bridado y modificado para permitir un fuerte agarre en condiciones húmedas o secas—,y un tope táctil confirma un cierre seguro. Preocúpese menos de la posibilidad de derrame o contaminación de contenidos esterilizados.
  • Una amplia superficie esmerilada de escritura en la botella receptora y el color más claro del tapón facilitan el etiquetado claro para mejorar la legibilidad y reducir los frotis ilegibles.
  • La tapa descansa sobre el lateral para evitar el riesgo de contaminación.
  • Las botellas receptoras son apilables para ahorrar espacio de almacenamiento.

Información legal

Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
Millipore is a registered trademark of Merck KGaA, Darmstadt, Germany
Stericup is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Questions

1–10 of 15 Questions  
  1. What is the chemical compatibility of the various Stericup® and Steritop® filters?

    What is the chemical compatibility of the various Stericup® and Steritop® filters?

    1 answer
    1. Helpful?

  2. What leachables are detected during filtration processes using Stericup® filters?

    1 answer
    1. We have not performed extractables/leachables studies for our Stericup® filters.

      Helpful?

  3. What is the difference between classic Stericup® filters and Stericup® “Quick Release” filters?

    1 answer
    1. Stericup® Quick Release, or “QR”, filters feature a connection between funnel filter and receiver bottle that requires only a quarter-turn release to facilitate funnel removal. These filters come fully engaged – there is no need to tighten before use. The receiver bottle cap has flanges on the top surface to improve grip, as well as a positive lock stop to ensure a leak-proof seal with the receiver bottle. Other improvements include a large, frosted writing surface on the receiver bottle and a lighter cap color to facilitate labelling, more prominent volume markings on the filtration funnel and receiver bottle, and a product label with a peel-off lot record strip on the bag for easy viewing in storage.

      Helpful?

  4. Can Stericup® and Steritop® filters be used to prepare solutions that will be administered to patients?

    1 answer
    1. No, all Stericup® and Steritop® devices are Research Use Only.

      Helpful?

  5. What is the expiration date of Stericup® and Steritop® filters?

    1 answer
    1. Typically 3 years from sterilization.

      Helpful?

  6. What is the maximum vacuum pressure for filtration?

    1 answer
    1. 700 mm Hg (27.5” Hg, 0.9 bar) differential vacuum at 25 °C (77 °F)

      Helpful?

  7. Can Stericup® and Steritop® filters be reused?

    1 answer
    1. All Stericup® and Steritop® filters were developed for single use, disposable processing.

      Helpful?

  8. Can we filter oil-type liquids with Stericup® filters?

    Can we filter oil-type liquids with Stericup® filters?

    1 answer
    1. Likely not, due to pore size/possible fouling/chemical compatibility. Refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf

      Helpful?

  9. What is the maximum processing volume for Stericup® and Steritop® filters? Can I add more volume after initial filtration?

    1 answer
    1. All Stericup® and Steritop® filters were developed for single-use application. The maximum volume is dependent on the receiver bottle capacity. Stericup® filters come with a receiver bottle with a specified maximum volume. For Steritop® filters, the maximum recommended volume is 2 L with an appropriate-sized receiver bottle. Larger processing volumes can result in membrane fouling, increase chance of spillage and contamination, and lead to possible airlock*.
      *Note that devices with PES membranes can airlock if filtered to dryness. Some liquid must be left on top of the filter, then the system stopped, receiver changed or emptied, and more sample volume added before restart. This increases the chance of spillage.

      Helpful?

  10. Can Stericup® bottles be placed inside freezers for long-term storage of media?

    1 answer
    1. You can successfully freeze and store many aqueous solutions (such as culture media) in Stericup® bottles at temperatures up to -20 °C (-4 °F). It is strongly recommended that you run a sample stability trial under your actual storage conditions prior to using Stericup® bottles for frozen storage.

      Helpful?

1–10 of 15 Questions  

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico