Saltar al contenido
Merck

445746

Sigma-Aldrich

Poly(methyl methacrylate)

average Mw ~350,000 by GPC

Sinónimos:

PMMA

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula lineal:
[CH2C(CH3)(CO2CH3)]n
Número de CAS:
MDL number:
UNSPSC Code:
12162002
PubChem Substance ID:
NACRES:
NA.23

form

powder

autoignition temp.

580 °F

mol wt

average Mw ~350,000 by GPC

reduced viscosity

150-160 cm3/g(20 °C)(lit.)

acid number

<1 mg KOH/g

transition temp

Tg (DSC) 105 °C (midpoint)

solubility

alcohols and aliphatic hydrocarbons: insoluble
esters, ketones, aromatics and glycol ethers: soluble

density

1.17 g/mL at 25 °C

InChI

1S/C5H9O2/c1-4(2)5(6)7-3/h1-3H3

Inchi Key

PMAMJWJDBDSDHV-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

General description

The thermal degradation behaviour of PMMA ( avg Mol. wt. ~350,000 g mol-1)was investigated in inert atmosphere, four weight loss steps were observed.

Application

PMMA (avg. Mol wt. ~350,000 g mol-1) containing Fe2O3 and TiO2 fillers have possible uses as flame retardants.
Pigment-wetting binder for coatings.

Features and Benefits

Contributes hardness, weather resistance, light fastness and resistance to chemicals.

Storage Class

11 - Combustible Solids

wgk_germany

nwg

ppe

Eyeshields, Gloves, type N95 (US)


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Influence of TiO2 and Fe2O3 fillers on the thermal properties of poly (methyl methacrylate)(PMMA).
Laachachi A.,et al.
Material Matters, 59(1), 36-39 (2005)
Thermal degradation of poly (methyl methacrylate)(PMMA): modelling of DTG and TG curves.
Ferriol M., et al.
Polymer Degradation and Stability, 79(2), 271-281 (2003)
S A Bini et al.
The bone & joint journal, 95-B(3), 367-370 (2013-03-02)
We evaluated the impact of pre-coating the tibial component with polymethylmethacrylate (PMMA) on implant survival in a cohort of 16 548 primary NexGen total knee replacements (TKRs) in 14 113 patients. In 13 835 TKRs a pre-coated tray was used
Pleural infection 55 years after plombage for pulmonary tuberculosis.
Qian-kun Chen et al.
Asian cardiovascular & thoracic annals, 21(1), 100-100 (2013-02-23)
Gursukhman S Sidhu et al.
Journal of neurosurgery. Spine, 19(1), 61-70 (2013-05-07)
The authors endeavor to highlight the surgical management of severe neurological deficit resulting from cement leakage after percutaneous vertebroplasty and to systematically review the literature on the management of this complication. A patient presented after a vertebroplasty procedure for traumatic

Artículos

The detection and quantification of biomarkers are essential for medical diagnostics, environmental monitoring, and bioresearch.

Professor Aran discusses engineering graphene-based materials through careful functionalization, enabling diverse applications.

Professor Aran discusses engineering graphene-based materials through careful functionalization, enabling diverse applications.

Professor Aran discusses engineering graphene-based materials through careful functionalization, enabling diverse applications.

Ver todo

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico