Accéder au contenu
Merck
Toutes les photos(4)

Principaux documents

P6757

Sigma-Aldrich

PIPES

≥99% (titration)

Synonyme(s) :

Acide 1,4-pipérazinediéthanesulfonique, Acide pipérazine-N,N′-bis(2-éthanesulfonique), Pipérazine-1,4-bis(acide 2-éthanesulfonique)

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule empirique (notation de Hill):
C8H18N2O6S2
Numéro CAS:
Poids moléculaire :
302.37
Beilstein:
817713
Numéro CE :
Numéro MDL:
Code UNSPSC :
12161700
ID de substance PubChem :
Nomenclature NACRES :
NA.25
Le tarif et la disponibilité ne sont pas disponibles actuellement.

Niveau de qualité

Essai

≥99% (titration)

Forme

crystalline powder

Plage de pH utile

6.1-7.5

pKa (25 °C)

6.8

Pf

>300 °C (lit.)

Solubilité

1 M NaOH: 20 + 80 mL g, clear, colorless

Application(s)

diagnostic assay manufacturing

Chaîne SMILES 

OS(=O)(=O)CCN1CCN(CC1)CCS(O)(=O)=O

InChI

1S/C8H18N2O6S2/c11-17(12,13)7-5-9-1-2-10(4-3-9)6-8-18(14,15)16/h1-8H2,(H,11,12,13)(H,14,15,16)

Clé InChI

IHPYMWDTONKSCO-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Le PIPES fait partie de la famille des tampons acide éthanesulfonique, introduits pour la première fois par Good et al.[1] et conçus pour répondre à certains critères : pKa intermédiaire, solubilité maximale dans l'eau et minimale dans les autres solvants, effet de sel réduit, faible variation du pKa avec la température, stabilité chimique et enzymatique, faible absorption dans le spectre UV ou visible et synthèse aisée. Avec un pKa à 37 °C proche du pH physiologique, le PIPES trouve des applications en culture cellulaire.

Application

La fixation au glutaraldéhyde d'échantillons de tissus végétaux et animaux peut s'accompagner d'une perte de lipides, entraînant des changements morphologiques visibles. L'utilisation de PIPES pour tamponner le glutaraldéhyde permet de limiter la perte lipidique et les artéfacts[2],[3]
Chez le rat, certains organites hépatocytaires subissent une perte sélective de l'activité phosphatase alcaline lorsque les cellules sont fixées au glutaraldéhyde tamponné au cacodylate en vue d'une analyse ultracytochimique. L'utilisation de PIPES comme tampon permet d'augmenter la rétention de cette activité de 60 %.[4]
La fixation de zoospores de champignons en vue d'une microscopie de fluorescence et d'une microscopie électronique est optimale avec un mélange de glutaraldéhyde et de formaldéhyde dans un tampon PIPES.[5]

Liaison

Sigma-Aldrich propose du PIPES certifié BioPerformance testé sur cultures cellulaires (réf. P1851) et différents sels pour faciliter la préparation de tampons, ainsi que le produit PIPES BioXtra (réf. P8203) qui est testé pour la présence de traces de métaux.

Notes préparatoires

Les tampons peuvent être préparés en ajoutant une solution de base au PIPES (acide libre) à titrer, au pH approprié, ou en mélangeant des solutions équimolaires du sel monosodique et du sel disodique à titrer, au pH approprié.

Code de la classe de stockage

11 - Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable

Équipement de protection individuelle

Eyeshields, Gloves, type N95 (US)


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Les clients ont également consulté

Slide 1 of 3

1 of 3

The role of the buffer in the fixation of biological specimens for transmission and scanning electron microscopy
Schiff, R.I. and Gennaro, J.F., Jr.
Scanning, 2, 135-135 (1979)
Use of PIPES buffer in the fixation of plant cells for electron microscopy
Salema, R. and Brandao, I.
Journal of Submicroscopic Cytology, 9, 79-79 (1973)
K Yamamoto et al.
Histochemistry, 77(3), 339-351 (1983-01-01)
Effects of NaOH-PIPES buffer used as a vehicle for aldehyde fixative on alkaline phosphatase (ALPase) activity demonstrated cyto- and biochemically were compared with those of routinely used cacodylate buffer. The reaction products showing ALPase activity demonstrated ultracytochemically were confined to
A R Hardham
The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society, 33(2), 110-118 (1985-02-01)
The study of the surface properties of zoospores and cysts of the fungus Phytophthora cinnamomi required a fixation regime that would preserve the cells adequately and not interfere with binding and detection of probes on the cell surface. When they
Buffers for enzymes.
J S Blanchard
Methods in enzymology, 104, 404-414 (1984-01-01)

Contenu apparenté

Find solutions for bulk production, custom packaging, and personalized chemical services to meet your unique research, development, and manufacturing requirements in your industries, including pharmaceuticals, biotechnology, and research institutions.

Discover high-purity biological buffers for production scale. Ensure stability, pH control, and consistent supply with our expert manufacturing solutions.

Discover high-purity biological buffers for production scale. Ensure stability, pH control, and consistent supply with our expert manufacturing solutions.

Discover high-purity biological buffers for production scale. Ensure stability, pH control, and consistent supply with our expert manufacturing solutions.

Afficher tout

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique