Saltar al contenido
Merck

45754

Sigma-Aldrich

Ácido acético solution

suitable for HPLC

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización

Seleccione un Tamaño

100 ML
$89.300
500 ML
$321.800

$89.300


Fecha estimada de envío27 de abril de 2025


Solicitar un pedido a granel

Seleccione un Tamaño

Cambiar Vistas
100 ML
$89.300
500 ML
$321.800

About This Item

Fórmula lineal:
CH3CO2H
Número de CAS:
Peso molecular:
60.05
Beilstein:
506007
Número MDL:
Código UNSPSC:
12352106
ID de la sustancia en PubChem:
NACRES:
NA.21

$89.300


Fecha estimada de envío27 de abril de 2025


Solicitar un pedido a granel

Agency

suitable for ASTM® 7968
suitable for ASTM® 7979
suitable for DIN 38407-42
suitable for EPA 1633
suitable for EPA 533
suitable for EPA 8327
suitable for EPA ACB B21-02
suitable for ISO 21675 2019
suitable for ISO 25101
suitable for ISO/CEN 15968-2010

Nivel de calidad

Formulario

liquid

concentración

49-51% (T)

técnicas

HPLC: suitable

densidad

1.049 g/cm3

λ

neat

Absorción UV

λ: 260 nm Amax: 0.05
λ: 270 nm Amax: 0.02
λ: 300 nm Amax: 0.01
λ: 500 nm Amax: 0.01

idoneidad

corresponds to standard for RP gradient test
corresponds to standard for filter test

cadena SMILES

CC(O)=O

InChI

1S/C2H4O2/c1-2(3)4/h1H3,(H,3,4)

Clave InChI

QTBSBXVTEAMEQO-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Descripción general

Acetic acid is an organic carboxylic acid. It is a pungent smelling hygroscopic liquid. Glacial acetic acid is the anhydrous acetic acid. It forms dimers linked by hydrogen bonds in solution and gaseous commonly referred as phases. It is weakly acidic in nature.[1]
Acetic acid is an organic carboxylic acid. It is a pungent-smelling hygroscopic liquid. Glacial acetic acid is an anhydrous acetic acid. It forms dimers linked by hydrogen bonds in solution and gaseous commonly referred to as phases. It is weakly acidic in nature.

Aplicación

The product is an HPLC buffer.
Used as a solvent/reagent in:
  • Extraction of E. coli based porphyrin for subsequent LC-MS/MS analysis
  • HPLC quantification of carbohydrate composition in sugarcane bagasse pulp

Productos recomendados

Discover LiChropur reagents ideal for HPLC or LC-MS analysis

Información legal

ASTM is a registered trademark of American Society for Testing and Materials

Pictogramas

FlameCorrosion

Palabra de señalización

Danger

Frases de peligro

Clasificaciones de peligro

Eye Dam. 1 - Flam. Liq. 3 - Skin Corr. 1B

Código de clase de almacenamiento

3 - Flammable liquids

Clase de riesgo para el agua (WGK)

WGK 1

Punto de inflamabilidad (°F)

104.0 °F - closed cup

Punto de inflamabilidad (°C)

40 °C - closed cup


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Los clientes también vieron

Slide 1 of 2

1 of 2

H-C Ni et al.
Acta biomaterialia, 6(6), 2066-2076 (2009-12-31)
Surface modification is a conventional approach in biomaterials development, but most of the modification processes are intricate and time inefficient. In this study, a convenient open air plasma treatment was employed to modify the surface of poly(d,l-lactide) (PLA). Chitosan and
D P Jones et al.
Clinica chimica acta; international journal of clinical chemistry, 275(2), 175-184 (1998-08-28)
Literature values for human plasma GSH vary over 10-fold despite the use of apparently valid analytical procedures for GSH measurement. The purpose of this study was to develop a procedure to minimize error in sample collection, processing and storage that
C M Davies et al.
European cells & materials, 11, 57-75 (2006-04-14)
This paper introduces the culture preparation of ovine, bovine and human cancellous bone cores to be used in an explants model Zetos. The three dimensional (3D) bone cores were prepared and evaluated for all three animals. Bone cells in vivo
Eagleson M.
Concise Encyclopedia Chemistry, 5-5 (1994)
John E P Syka et al.
Proceedings of the National Academy of Sciences of the United States of America, 101(26), 9528-9533 (2004-06-24)
Peptide sequence analysis using a combination of gas-phase ion/ion chemistry and tandem mass spectrometry (MS/MS) is demonstrated. Singly charged anthracene anions transfer an electron to multiply protonated peptides in a radio frequency quadrupole linear ion trap (QLT) and induce fragmentation

Contenido relacionado

FAS, or 'forever chemicals,' persist in the environment and pose risks to human health. Discover our environmental monitoring tools for PFAS quantification, aiding researchers, regulators, and labs in testing for PFAS.

Las PFAS o «productos químicos eternos», persisten en el medio ambiente y pueden suponer un riesgo para la salud humana. Descubra nuestras herramientas de control medioambiental para cuantificación de las PFAS, para apoyar a los investigadores, reguladores y laboratorios en sus análisis de las PFAS.

Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. 농도 궁금합니다. 45754 제품 구매했고 HPLC  standard 로 사용하려고하는데 농도가 어떻게 되는걸까요?? 설명에 나와있는 NaOH 적정량 50% acetic acid 라고 보면 되는건가요?

    1 answer
    1. This product is a 50% solution with a concentration specification of 49.0-51.0%. The exact concentration will be listed on the lot-specific Certificate of Analysis. Please navigate to the DOCUMENTATION section of the Product Detail Page to access a Certificate under ‘Certificate of Analysis’:
      https://www.sigmaaldrich.com/product/sigald/45754#product-documentation

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico