34036
Aflatoxin Mix 4 solution
analytical standard
About This Item
Productos recomendados
grade
analytical standard
shelf life
limited shelf life, expiry date on the label
concentration
0.5 μg/mL B2 and G2 in acetonitrile
2 μg/mL B1 and G1 in acetonitrile
technique(s)
HPLC: suitable
gas chromatography (GC): suitable
application(s)
cleaning products
cosmetics
food and beverages
personal care
format
multi-component solution
storage temp.
−20°C
¿Está buscando productos similares? Visita Guía de comparación de productos
General description
Application
This aflatoxin mix 4 solution was used as follows:
- Ultra-high-performance liquid chromatography-fluorescence detection (UHPLC-FLD) based quantification of aflatoxins— B1, B2, G1, and G2, in the coffee bean and powder samples
- Estimation of aflatoxins (B1, B2, G1, and G2) in samples of maize, rice, sorghum meal, and peanuts by ultra high-performance liquid chromatography coupled with a fluorescence detector
- Determination of naturally occurring aflatoxins in 65 peanut-enriched flour samples by high-performance liquid chromatography (HPLC) combined with fluorescence detection
Other Notes
signalword
Danger
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
Storage Class
3 - Flammable liquids
wgk_germany
WGK 2
flash_point_f
35.6 °F - closed cup
flash_point_c
2 °C - closed cup
ppe
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Los clientes también vieron
Artículos
Analyte recovery values from spiked cannabis extracts ranged from 102 to 127% with RSD below 12% for 3 replicates. Excellent recovery values were even observed for Aflatoxins B2 and G2 which were spiked at a low level of 6.1 ppb.
Supel Tox AflaZea SPE improves analyte recovery with less sample volume, while HPLC confirms effective elimination of interferences.
Cannabis testing regulations include analysis of purity, potency, and contaminants. Learn more about analysis of cannabis for pesticides, mycotoxins, and pyrethrins registered in California by LC-MS/MS and GC-MS/MS Using Ascentis® Express Biphenyl and SLB®-5ms Columns
Protocolos
solution, 2 μg/mL in acetonitrile, analytical standard
Contenido relacionado
Detailed list of mycotoxin analysis products for Food & Beverage manufacturers and testers, ensuring safety standards.
Chromatograms
application for HPLCapplication for HPLCNuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico