Passa al contenuto
Merck
  • Development and validation of a hydrophilic interaction liquid chromatography with tandem mass spectrometry method for the simultaneous detection and quantification of etilefrine and oxilofrine in equine blood plasma and urine.

Development and validation of a hydrophilic interaction liquid chromatography with tandem mass spectrometry method for the simultaneous detection and quantification of etilefrine and oxilofrine in equine blood plasma and urine.

Journal of separation science (2014-08-22)
Noel Kong, Rong Yi, Sarah Zhao, Jasmeet Sandhu, Geoffrey Lam, Devan Loganathan, Barbara Morrissey
ABSTRACT

A sensitive hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry method was developed and validated for the simultaneous detection and quantification of etilefrine and oxilofrine in equine blood plasma and urine. The method is highly sensitive and specific with good precision and accuracy. In plasma the limit of detection and limit of quantification are 0.03 and 0.1 ng/mL, respectively, for both analytes. In urine the limit of detection and limit of quantification are 0.3 and 1 ng/mL, respectively, for both analytes. The suitability of the method for doping control analysis in equine species is demonstrated by analyzing postadministration samples collected after a single intravenous administration of 50 mg etilefrine to a standardbred mare. Etilefrine was detected up to 120 h in urine and up to 48 h in plasma. Etilefrine is highly conjugated in equine urine whereas it exists in the free form in equine plasma. Therefore, enzyme hydrolysis prior to sample preparation is recommended for the detection and quantification of etilefrine and oxilofrine in equine urine.

MATERIALI
N° Catalogo
Marchio
Descrizione del prodotto

Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanolo, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Idrossido di ammonio, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Metanolo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acido formico, reagent grade, ≥95%
Sigma-Aldrich
Metanolo, HPLC Plus, ≥99.9%
Sigma-Aldrich
ter-butil metil etere, suitable for HPLC, ≥99.8%
Sigma-Aldrich
Acido formico, ACS reagent, ≥96%
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acido formico, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
Idrossido di ammonio, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
Ammoniaca, 7 N in methanol
Sigma-Aldrich
Acetonitrile, for HPLC, for UV, ≥99.9% (GC)
Sigma-Aldrich
ter-butil metil etere, ACS reagent, ≥99.0%
Sigma-Aldrich
Formato di ammonio, reagent grade, 97%
Sigma-Aldrich
Acetato di sodio, ACS reagent, ≥99%
Sigma-Aldrich
Sodium tetraborate decahydrate, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
ter-butil metil etere, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
Metanolo, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Metanolo, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Supelco
Formato di ammonio, eluent additive for LC-MS, LiChropur, ≥99.0%
Sigma-Aldrich
Metanolo, anhydrous, 99.8%
Sigma-Aldrich
Metanolo, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Idrossido di ammonio, puriss., 30-33% NH3 in H2O
Sigma-Aldrich
Acido formico, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
Formato di ammonio, ≥99.995% trace metals basis