GE28-9269-79
HiScreen™ Capto™ S
Cytiva 28-9269-79
Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali
About This Item
Prodotti consigliati
ligand
sulfonate group
Descrizione
Ion Exchanger Type (value)
Confezionamento
pkg of 1 ea
Produttore/marchio commerciale
Cytiva 28-9269-79
Parametri
44 psi
Dimensioni del letto
7.7 mm × 100 mm
Volume del letto
4.7 mL
Diam. int. colonna
7.7 mm
Matrice
highly cross-linked agarose with dextran surface extender
Diametro medio
90 μm (d50v)
cleaning
3-14
working range
4-13
Compatibilità
suitable for bioprocess medium
Categorie correlate
Descrizione generale
HiScreen Capto S columns are prepacked with Capto S ion exchange chromatography medium, and are part of the process development platform available from Cytiva. The columns are an excellent choice for method optimization and parameter screening.
The small column volume of 4.7 mL and bed height of 10 cm make HiScreen columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, since the 10 cm bed height gives enough residence time and the results can then serve as basis for linear process scale-up.
If necessary, two columns can easily be connected in series to give a bed height of 2NA cm.
Media prepacked in HiScreen Capto IEX columns are also available in other formats and as bulk packs, which makes it possible to use the same media for development work, pilot studies, and routine production.
The small column volume of 4.7 mL and bed height of 10 cm make HiScreen columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, since the 10 cm bed height gives enough residence time and the results can then serve as basis for linear process scale-up.
If necessary, two columns can easily be connected in series to give a bed height of 2NA cm.
Media prepacked in HiScreen Capto IEX columns are also available in other formats and as bulk packs, which makes it possible to use the same media for development work, pilot studies, and routine production.
Caratteristiche e vantaggi
- Capto S is a strong cation exchange BioProcess medium, designed to meet the demands of modern large-scale manufacturers for fast, efficient, and cost-effective capture and intermediate protein purification.
- Prepacked, ready-to-use columns for convenient process development optimization.
- 1NA cm bed height of HiScreen columns is designed to allow method optimization and parameter screening.
- Easily connected in series to achieve 2NA cm bed height.
- Small bed volume gives fast results and minimal sample/buffer consumption.
- Reproducible results, scalable to BioProcess columns packed with the same media using the same linear fluid velocity.
Stoccaggio e stabilità
Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (0.2 M sodium acetate in 20% ethanol)
Store at 4 to 30 °C (20% Ethanol + 0.2 M Sodium Acetate)
Risultati analitici
To view the Certificate of Analysis for this product, please visit www.cytiva.com.
Note legali
Capto is a trademark of Cytiva
HiScreen is a trademark of Cytiva
Prodotti correlati
N° Catalogo
Descrizione
Determinazione del prezzo
Avvertenze
Warning
Indicazioni di pericolo
Consigli di prudenza
Codice della classe di stoccaggio
3 - Flammable liquids
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.