Millipore Express® SHC High Area 0.5/0.2µm, Opticap® XLT 10 Capsule

Fittings 1-1/2 in. TC- 1 in. HB, Gamma Compatible

Sinonimo/i:

Gamma Compatible High Area Opticap® XLT 10 Millipore Express® SHC 0.5  µm/ 0.2  µm 1-1/2 in. TC-1 in. HB

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
23151806
Prezzi e disponibilità al momento non sono disponibili

Nome del prodotto

Millipore Express® SHC High Area, Opticap® XLT Capsule, Opticap® XLT 10, non-sterile, pore size 0.5/0.2 μm, cartridge nominal length 10 in. (25 cm)

Materiali

polyester support
polyethersulfone
polypropylene
polypropylene housing
polypropylene vent cap
polysulfone
silicone seal

Livello qualitativo

Conformità normativa

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

Sterilità

non-sterile

Compatibilità con la sterilizzazione

gamma compatible

Nome Commerciale

Opticap® XLT 10

Caratteristiche

hydrophilic

Produttore/marchio commerciale

Millipore Express®

Parametri

≤56.4 mL/min air diffusion at 2.75 bar (40 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psi) at 80 °C (Forward)
2.1 bar max. differential pressure (30 psi) at 25 °C (Reverse; intermittent)
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psi) at 25 °C (Forward)
6.9 bar max. differential pressure (100 psi) at 25 °C (Forward; intermittent)
80 psig max. inlet pressure

tecniche

sterile filtration: suitable

Lunghezza

37.6 cm (14.8 in.)

Larghezza

4.2 in.

Lunghezza nominale della cartuccia

10 in. (25 cm)

Diametro

10.7 in. (4.2 cm)

Superficie filtrante

1.0 m2

Amp. ingresso/ uscita

17.5 cm (6.9 in.)

Diam. connessione uscita

1 in.

Impurezze

≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

Matrice

Millipore Express® SHC High Area

pore size

0.5/0.2 μm pore size

Punto di bolla

≥4000 mbar (58 psig), air with water at 23 °C

Raccordi

1/4 in. drain/vent hose barb (with double O-ring seal)
inlet sanitary flange
outlet hose barb
(38 mm (1 1/2 in.) Sanitary Flange Inlet and 25 mm (1 in.) Hose Barb Outlet)

applicazioni

sample preparation

Descrizione generale

T-line/Gauge Port: T-line

Confezionamento

Double Easy-Open bag

Altre note

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Nota sulla preparazione

Sterilization Method
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Risultati analitici

Bacterial Retention
Quantitative retention of 107 CFU/cm2Brevundimonas diminuta (ATCC® 19146) per HIMA methodology
TOC/Conductivity
After sterilization and a controlled water flush of 21 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L

Note legali

ATCC is a registered trademark of American Type Culture Collection
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Esclusione di responsabilità

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.

Cos’è il programma Emprove®?

Il programma Emprove® è un sistema ideato per garantire un’esauriente e approfondita documentazione sui nostri filtri e componenti monouso, sulle materie prime farmaceutiche e sugli “starting material”.

Material Qualification Dossier

Gratis - Registrati per scaricarlo

Quality Management Dossier (Open Access)

Gratis - Registrati per scaricarlo

Operational Excellence Dossier

Disponibile per gli abbonati o a pagamento

Scopri i benefici dell’abbonamento a un programma Emprove®
Perché questi documenti non sono disponibili?
I dossier Emprove® contengono informazioni destinate ad agevolare l'iter di registrazione e le attività per la valutazione del rischio dei produttori farmaceutici e includono informazioni riservate. Se desideri accedervi, per contattarci.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Questions

Reviews

No rating value

Active Filters

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.