KHGEG1TTB1H
Millipore Express® SHC High Area 0.5/0.2µm, Opticap® XLT 10 Capsule
Fittings 1-1/2 in. TC- 1 in. HB, Gamma Compatible
Sinonimo/i:
Gamma Compatible High Area Opticap® XLT 10 Millipore Express® SHC 0.5 µm/ 0.2 µm 1-1/2 in. TC-1 in. HB
About This Item
Prodotti consigliati
Nome del prodotto
Millipore Express® SHC High Area, Opticap® XLT Capsule, Opticap® XLT 10, non-sterile, pore size 0.5/0.2 μm, cartridge nominal length 10 in. (25 cm)
Materiali
polyester support
polyethersulfone
polypropylene
polypropylene housing
polypropylene vent cap
polysulfone
silicone seal
Livello qualitativo
Conformità normativa
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
Sterilità
non-sterile
Compatibilità con la sterilizzazione
gamma compatible
Nome Commerciale
Opticap® XLT 10
Caratteristiche
hydrophilic
Produttore/marchio commerciale
Millipore Express®
Parametri
≤56.4 mL/min air diffusion at 2.75 bar (40 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psi) at 80 °C (Forward)
2.1 bar max. differential pressure (30 psi) at 25 °C (Reverse; intermittent)
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psi) at 25 °C (Forward)
6.9 bar max. differential pressure (100 psi) at 25 °C (Forward; intermittent)
80 psig max. inlet pressure
tecniche
sterile filtration: suitable
Lunghezza
37.6 cm (14.8 in.)
Larghezza
4.2 in.
Lunghezza nominale della cartuccia
10 in. (25 cm)
Diametro
10.7 in. (4.2 cm)
Superficie filtrante
1.0 m2
Amp. ingresso/ uscita
17.5 cm (6.9 in.)
Diam. connessione uscita
1 in.
Impurezze
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
Matrice
Millipore Express® SHC High Area
pore size
0.5/0.2 μm pore size
Punto di bolla
≥4000 mbar (58 psig), air with water at 23 °C
Raccordi
1/4 in. drain/vent hose barb (with double O-ring seal)
inlet sanitary flange
outlet hose barb
(38 mm (1 1/2 in.) Sanitary Flange Inlet and 25 mm (1 in.) Hose Barb Outlet)
applicazioni
sample preparation
Descrizione generale
Confezionamento
Altre note
Nota sulla preparazione
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Risultati analitici
Quantitative retention of 107 CFU/cm2Brevundimonas diminuta (ATCC® 19146) per HIMA methodology
After sterilization and a controlled water flush of 21 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Note legali
Esclusione di responsabilità
Cos’è il programma Emprove®?
Il programma Emprove® è un sistema ideato per garantire un’esauriente e approfondita documentazione sui nostri filtri e componenti monouso, sulle materie prime farmaceutiche e sugli “starting material”.
Gratis - Registrati per scaricarlo
Gratis - Registrati per scaricarlo
Disponibile per gli abbonati o a pagamento
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Active Filters
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.