Direkt zum Inhalt
Merck

V900295

Sigma-Aldrich

CHES

Vetec, reagent grade, 99%

Synonym(e):

2-(Cyclohexylamino)-ethansulfonsäure

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Empirische Formel (Hill-System):
C8H17NO3S
CAS-Nummer:
Molekulargewicht:
207.29
Beilstein:
2967601
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
12161700
PubChem Substanz-ID:

Qualität

reagent grade

Produktlinie

Vetec

Assay

99%

Form

crystalline powder

pH-Wert

3.0-5.0 (103.6 g/L)

Nützlicher pH-Bereich

8.6-10.0

pKa (25 °C)

9.3

Löslichkeit

water: 0.176 g/mL, clear, colorless

SMILES String

OS(=O)(=O)CCNC1CCCCC1

InChI

1S/C8H17NO3S/c10-13(11,12)7-6-9-8-4-2-1-3-5-8/h8-9H,1-7H2,(H,10,11,12)

InChIKey

MKWKNSIESPFAQN-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Rechtliche Hinweise

Vetec is a trademark of Merck KGaA, Darmstadt, Germany

Lagerklassenschlüssel

11 - Combustible Solids

WGK

WGK 3

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Gauthier J-P Deblonde et al.
Dalton transactions (Cambridge, England : 2003), 48(23), 8238-8247 (2019-05-17)
The solution- and solid-state interactions between the octadentate siderophore mimic 3,4,3-LI(1,2-HOPO) (343HOPO) and group IV metal ions were investigated using high-resolution mass spectrometry, liquid chromatography, UV-visible spectrophotometry, metal-competition batch titrations, and single crystal X-ray diffraction. 343HOPO forms a neutral 1 : 1
Leo Lebanov et al.
The Analyst, 145(17), 5897-5904 (2020-07-17)
This work provides the pKa at the biorelevant temperature of 37 °C for a set of compounds proposed as internal standards for the internal standard capillary electrophoresis (IS-CE) method. This is a high throughput method that allows the determination of
Scott A Sarver et al.
Journal of chromatography. A, 1229, 268-273 (2012-02-11)
Several glycosphingolipids were labeled with the fluorphore Bodipy-Fl and analyzed using capillary electrophoresis with laser-induced fluorescence detection. GM1-, LacCer-, and Cer-Bodipy-Fl were prepared through acylation using the N-hydroxysuccinimide ester of Bodipy-Fl. Several other glycosphingolipids including GT1a-, GD1a-, GM2-, GM3-, GD3-
P Doble et al.
Electrophoresis, 19(12), 2257-2261 (1998-10-07)
The suitability of relatively slow (low absolute value of mobility) coanionic buffers in background electrolytes (BGEs) for indirect photometric detection of anions by capillary electrophoresis was investigated. As a model system, 2-(cyclohexylamino)ethanesulfonic acid (CHES) was used to buffer the indirect
David G McLaren et al.
Electrophoresis, 24(17), 2887-2895 (2003-09-16)
A systematic evaluation of continuous flow-counterbalanced capillary electrophoresis for microscale preparative applications is presented. The success of the technique was found to depend on the specific nature of the analyte and background electrolyte and was most heavily influenced by factors

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.