1.50457
SeQuant™ ZIC®-HILIC 200Å (5 µm) HPLC Columns
L × I.D. 250 mm x 2.1 mm HPLC Column, PEEK-lined stainless steel
About This Item
Empfohlene Produkte
product name
SeQuant™ ZIC-HILIC™ 5µm,200Å 250 x 2.1 mm, PEEK-lined stainless steel column, suitable for HPLC
Materialien
PEEK-lined stainless steel column
Qualitätsniveau
Agentur
suitable for USP L114
Produktlinie
SeQuant™
Leistungsmerkmale
endcapped: no
Parameter
550 bar pressure
70 °C max. temp.
Methode(n)
HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
mass spectrometry (MS): suitable (High)
Säule L × ID
25 cm × 2.1 mm
Matrix
fully porous particle
Aktive Matrixgruppe
ZIC-HILIC bonding phase
Partikelgröße
5 μm
Porengröße
200 Å pore size
Betriebs-pH-Wert
2-7.5
Trenntechnik
hydrophilic interaction (HILIC)
Lagertemp.
no temp limit
Allgemeine Beschreibung
The silica-based ZIC®-HILIC sorbent has a bonded stationary phase consisting of a highly polar, permanent zwitterion. Separation selectivity is favored by the 1:1 zwitterion charge balance, which makes the ZIC®-HILIC Column overall neutral, with weak, but important, ionic interactions. Tuning of the selectivity on the ZIC®-HILIC Column during method development is facilitated by the pH-inpendent permanent zwitterion, ensuring that only the analytes (and not the column) are affected during eluent optimization.
The Pore size of 200 Å makes this column perfectly suitable for the separation of larger polar molecules under HILIC conditions.
The column dimension of 250 mm length x 2.1 mm ID is the optimal choice for the separation of complex samples using a UHPLC or optimized HPLC Instrument providing low dwell volumes.
Thanks to their favorable retention and robust performance, SeQuant™ HILIC columns have become extremely popular in numerous laboratories around the world. For example, US FDA (United States Food and Drug Administration) has recommended SeQuant™ ZIC®-HILIC for analysis of melamine and related substances.
SeQuant™ HILIC columns excel in stability and low bleed. These features make them particularly suitable for LC-MS applications where high background can lead to signal suppression and interference with quantitative measurements while also increasing instrument wear. Their high stability makes these high-performance HILIC columns also attractive for traditional HPLC applications.
Learn more about the Supelco HPLC Column portfolio and Method development:
Brochure: HPLC and UHPLC Column Selection Guide
Brochure: A Practical Guide to HPLC - Method Development Guide
Hinweis zur Analyse
Symmetrie (Cytosine): 0.95 - 1.40
Rechtliche Hinweise
Ähnliches Produkt
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.