Accéder au contenu
Merck
Toutes les photos(1)

Documents

16001

Sigma-Aldrich

Brij® L4

main component: tetraethylene glycol dodecyl ether

Synonyme(s) :

Polyethylene glycol dodecyl ether

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Numéro CAS:
Numéro Beilstein :
1900171
Numéro MDL:
Code UNSPSC :
12161900
ID de substance PubChem :

Description

non-ionic

Technique(s)

protein quantification: suitable

Indice de réfraction

n20/D 1.453

HLB

9.7

Densité

~0.95 g/mL at 20 °C

Chaîne SMILES 

CCCCCCCCCCCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCO

InChI

1S/C58H118O24/c1-2-3-4-5-6-7-8-9-10-11-13-60-15-17-62-19-21-64-23-25-66-27-29-68-31-33-70-35-37-72-39-41-74-43-45-76-47-49-78-51-53-80-55-57-82-58-56-81-54-52-79-50-48-77-46-44-75-42-40-73-38-36-71-34-32-69-30-28-67-26-24-65-22-20-63-18-16-61-14-12-59/h59H,2-58H2,1H3

Clé InChI

IEQAICDLOKRSRL-UHFFFAOYSA-N

Attention

product may precipitate on storage, resolve at 50°C

Informations légales

Brij is a registered trademark of Croda International PLC

Pictogrammes

Exclamation markEnvironment

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Irrit. 2

Code de la classe de stockage

11 - Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable

Équipement de protection individuelle

dust mask type N95 (US), Eyeshields, Gloves


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Jun Koizumi et al.
AJR. American journal of roentgenology, 199(1), 200-207 (2012-06-27)
Balloon-occluded retrograde transvenous obliteration has been traditionally based on liquid sclerotherapy. However, overdose and systemic spillage of liquid sclerosant can cause severe complications, such as hemolysis, which lead to hemoglobinuria, allergy, acute respiratory distress syndrome, and other disorders. The purpose
A Erkin et al.
European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery, 44(6), 593-597 (2012-11-06)
Foam sclerosants are widely used in sclerotherapy and have been accepted as more effective than the liquid form; however, there is no consensus about the most applicable and effective concentration. The aim of this study was to investigate the histopathological
Otte Brosjö et al.
Acta orthopaedica, 84(5), 502-505 (2013-11-01)
Recent data suggest that percutaneous sclerotherapy is a safe alternative to surgery for treatment of aneurysmal bone cysts (ABCs). We present our experience of this method. We retrospectively analyzed data from 38 consecutive patients treated with repeated injections of polidocanol.
Jacomina W van den Esschert et al.
Annals of surgery, 255(2), 311-318 (2012-01-14)
To compare the safety and hypertrophy response after portal vein embolization (PVE) using 2 absorbable and 3 permanent embolization materials. Portal vein embolization is used to increase future remnant liver volume preoperatively. Application of temporary, absorbable embolization materials could be
Amish Patel et al.
AJR. American journal of roentgenology, 199(4), 721-729 (2012-09-22)
The purpose of this review is to describe the clinical factors related to balloon-occluded retrograde transvenous obliteration, including the preparation needed, the technique and challenges, and the outcomes. Although the procedure can be performed when transjugular intrahepatic portosystemic shunt is

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique