MABS1250

Sigma-Aldrich

Anti-Mineralocorticoid Receptor Antibody, clone 2D6

clone 2D6, from mouse

Synonyme(s) :

MR, Nuclear receptor subfamily 3 group C member 2, Mineralocorticoid Receptor

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12352203
eCl@ss :
32160702
Nomenclature NACRES :
NA.43

Source biologique

mouse

Niveau de qualité

Forme d'anticorps

purified immunoglobulin

Type de produit anticorps

primary antibodies

Clone

2D6, monoclonal

Espèces réactives

rat

Technique(s)

immunocytochemistry: suitable
immunohistochemistry: suitable
western blot: suitable

Isotype

IgG2aκ

Numéro d'accès NCBI

Numéro d'accès UniProt

Conditions d'expédition

wet ice

Modification post-traductionnelle de la cible

unmodified

Informations sur le gène

Description générale

Mineralocorticoid receptor (UniProt P22199; also known as MR, Nuclear receptor subfamily 3 group C member 2) is encoded by the Nr3c2 (also known as MCR, Mlr) gene (Gene ID 25672) in rats. Mineralocorticoid receptor (MR) is expressed in multiple tissues, including renal epithelia, smooth muscle, endothelium, cardiomyocytes, and hippocampal neurons, where it mediates diverse functions. MR is activated by aldosterone and also by cortisol in cells that do not express 11β-hydroxysteroid dehydrogenase type 2 (11βHSD2). MR is normally activated by aldosterone, which is produced by adrenal glomerulosa in response to intravascular volume depletion and hyperkalemia. Consistently, gain of function mutations in MR lead to severe hypertension, often with hypokalemia, while loss of function mutations result in neonatal hypotension. Ser843 phosphorylation in the MR ligand-binding domain is reported to prevent MR ligand binding and activation. MR pS843 is found exclusively in intercalated cells of the distal nephrons in the kidney. Intravascular volume depletion, angiotensin II and WNK4 signaling reduce MR pS843 levels, whereas hyperkalemia increases MR pS843.

Spécificité

Epitope is present in all 3 alternative spliced isoforms

Immunogène

Conjugated linear peptide corresponding to the N-terminus of rat Mineralocorticoid Receptor.
Epitope: Near N-terminus

Application

Detect Mineralocorticoid Receptor using this Anti-Mineralocorticoid Receptor Antibody, clone 2D6 validated for use in Western Blotting, Immunohistochemistry and Immunocytochemistry.
Immunohistochemistry Analysis: A representative lot detected Mineralocorticoid Receptor in hippocampus, dentate gyrate, choroid plexus, heart, and rat kidney (Gomez-Sanchez, C.E., et al. (2006). Endocrinology. 147(3):1343-1348).
Immunocytochemistry Analysis: A representative lot detected Mineralocorticoid Receptor in mouse kidney (Shibata, S., et al. (2013). Cell Metabolism. 18:660-671).
Western Blotting Analysis: A representative lot detected endogenous Mineralocorticoid Receptor (MR) in rat hippocampal cytosolic preparation and exogenously expressed EGFP-rat MR fusion protein in CHO cells (Gomez-Sanchez, C.E., et al. (2006). Endocrinology. 147(3):1343-1348).
Western Blotting Analysis: A representative lot detected endogenous Mineralocorticoid Receptor (MR) in mouse kidney cytosolic fraction and exogenously expressed human MR in COS-7 cells (Shibata, S., et al. (2013) Cell Metab. 18(5):660-671)
Research Category
Signaling
Research Sub Category
Signaling Neuroscience

Qualité

Evaluated by Western Blotting in rat brain cytosol tissue lysate.

Western Blotting Analysis: A 1:500 dilution of this antibody detected Mineralocorticoid Receptor in 10 µg of rat brain cytosol tissue lysate.

Description de la cible

~107 kDa observed

Forme physique

Format: Purified
Protein G Purified
Purified mouse monoclonal IgG2aκ in buffer containing 0.1 M Tris-Glycine (pH 7.4), 150 mM NaCl with 0.05% sodium azide.

Stockage et stabilité

Stable for 1 year at 2-8°C from date of receipt.

Autres remarques

Concentration: Please refer to lot specific datasheet.

Clause de non-responsabilité

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Vous ne trouvez pas le bon produit ?  

Essayez notre Outil de sélection de produits.

Code de la classe de stockage

12 - Non Combustible Liquids

Classe de danger pour l'eau (WGK)

WGK 1

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique