KTGRA10FF1
Aervent® 0,2 µm, capsule Opticap® XL
Opticap® XL 10, pore size 0.2 μm, hydrophobic, 19 mm (3/4 in.) inlet/outlet sanitary flange, non-sterile, sterilization compatible with autoclavable
Synonyme(s) :
Aervent KTGR Opticap XL10 Capsule
About This Item
Produits recommandés
Matériaux
PTFE
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
silicone seal
Niveau de qualité
Stérilité
non-sterile
Mode de stérilisation compatible
autoclavable compatible
Gamme de produits
Opticap® XL 10
Caractéristiques
hydrophobic
Fabricant/nom de marque
Aervent®
Paramètres
≤24 mL/min air diffusion at 965 mbar (14 psig) and 23 °C (in 70/30%IPA/water)
≤24 mL/min nitrogen diffusion at 970 mbar (14 psig) and 23 °C (in 70/30% IPA/water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C (Forward)
2.8 bar max. inlet pressure (40 psi) at 60 °C (Forward)
25 °C max. inlet temp.
4.1 bar max. differential pressure (60 psid) (Reverse; intermittent)
4.1 bar max. inlet pressure (60 psi) (Reverse; Intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C (Forward)
80 psig max. inlet pressure
Technique(s)
gas filtration: suitable
Longueur
13.2 in.
Largeur
4.2 in.
Longueur nominale des cartouches
10 in. (25 cm)
Diamètre
10.7 cm (4.2 in.)
Surface de filtration
0.65 m2
Diam. du raccord d'entrée
3/4 in.
Largeur, de l'entrée à la sortie
33.0 cm (13.0 in.)
Diam. du raccord de sortie
3/4 in.
Impuretés
<0.25 EU/mL USP bacterial endotoxins (LAL test, aqueous extraction)
Extractibles par gravimétrie
≤45 mg/cartridge
Matrice
Aervent®
Dimension de pores
0.2 μm pore size
Entrée
sample type gas
Point de bulle
≥1100 mbar (16 psig), nitrogen with 70/30% IPA/water at 23 °C
Raccords
19 mm (3/4 in.) inlet/outlet sanitary flange
Vous recherchez des produits similaires ? Visite Guide de comparaison des produits
Description générale
Conditionnement
Qualité
Notes préparatoires
30 autoclave cycles of 30 min @ 135 °C
Remarque sur l'analyse
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Autres remarques
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Steam Sterilization & Integrity Testing Procedures guide and first page of Visual Inspection Guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Informations légales
Clause de non-responsabilité
Vous ne trouvez pas le bon produit ?
Essayez notre Outil de sélection de produits.
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique