Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

613544

Sigma-Aldrich

TMB, Soluble

Synonyme(s) :

TMB, Soluble, 3,3ʹ,5,5ʹ-Tetramethylbenzidine

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Numéro CAS:
Numéro MDL:
Code UNSPSC :
41116133
Nomenclature NACRES :
NA.41

Forme

liquid

Niveau de qualité

Ne contient pas

preservative

Fabricant/nom de marque

Calbiochem®

Conditions de stockage

OK to freeze
protect from light

Couleur

clearvery light blue

Conditions d'expédition

ambient

Température de stockage

2-8°C

InChI

1S/C16H20N2/c1-9-5-13(6-10(2)15(9)17)14-7-11(3)16(18)12(4)8-14/h5-8H,17-18H2,1-4H3

Clé InChI

UAIUNKRWKOVEES-UHFFFAOYSA-N

Description générale

Peroxidase substrate that produces a blue soluble end product that can be read at 370 nm or 650 nm. Use of stop solution enhances sensitivity two- to four-fold and results in a yellow solution that can be read at 450 nm.
Soluble TMB substrate supplied as a single component system.

Avertissement

Toxicity: Irritant (B)

Forme physique

Single component system containing 1.46 mM TMB, 2.21 mM H₂O₂ in a proprietary solvent, pH 3.1 ± 0.5.

Reconstitution

Protect from exposure to direct sunlight. Discard if the solution turns blue or turbid. The reagent is stable at room temperature, but we recommend storage in the refrigerator for longer shelf life. Warm to assay temperature before use.

Autres remarques

Product tested for stability at 4°C and 18-26°C. Product performance is tested on the final product by ELISA.



Suggested Procedure for Use of TMB in HRP-based ELISAs:



1. Complete all required incubations with antibodies and HRP-labeled probes.

2. Wash plate wells at least 4 times with phosphate-buffered saline (PBS) or Tris-buffered saline (TBS), containing 0.1% Tween®-20 detergent.

3. After the final wash, shake and blot all residual buffer from the wells.

4. Add 100 μl TMB solution to each well and incubate for 5-30 min.

5. Options for measurements:

a. For kinetic assays, the reaction can be monitored as a function of time by reading absorbance at 650 nm at intermediate intervals.

b. For endpoint assays that preserve the blue chromogen, the reaction should be stopped by addition of 100 µl of 0.1% sodium fluoride (NaF) and the absorbance read at 650 nm.

c. If increased sensitivity is desired for endpoint assays, the reaction should be stopped by addition of 100 μl of either 500 mM H2SO4 or 250 mM HCl and the absorbance read at 450 nm WITHIN 5 MIN. Addition of acid converts the blue radical to the yellow diimine, which absorbs at 450 nm.



NOTE: Optimal incubation times may vary depending on the amount of HRP present. If color develops too quickly, zero-order kinetics will not prevail. Dilution of the probe, antibody, or HRP-labeled reagent may be required. Variations in time, reagent volumes, and temperature may also require further standardization by the user.

Informations légales

CALBIOCHEM is a registered trademark of Merck KGaA, Darmstadt, Germany
TWEEN is a registered trademark of Croda International PLC

Pictogrammes

Health hazardExclamation mark

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Acute Tox. 4 Oral - Aquatic Chronic 4 - Carc. 2

Code de la classe de stockage

11 - Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique