Accéder au contenu
MilliporeSigma

Seasonal trends of atmospheric nitrogen dioxide and sulfur dioxide over North Santa Clara, Cuba.

Environmental monitoring and assessment (2012-12-05)
Daniellys Alejo, Mayra C Morales, Jorge B de la Torre, Ricardo Grau, László Bencs, René Van Grieken, Piet Van Espen, Dismey Sosa, Vladimir Nuñez
RÉSUMÉ

Atmospheric nitrogen dioxide (NO2) and sulfur dioxide (SO2) levels were monitored simultaneously by means of Radiello passive samplers at six sites of Santa Clara city, Cuba, in the cold and the warm seasons in 2010. The dissolved ionic forms of NO2 and SO2 as nitrate and sulfite plus sulfate, respectively, were determined by means of ion chromatography. Analysis of NO2 as nitrite was also performed by UV-Vis spectrophotometry. For NO2, significant t tests show good agreement between the results of IC and UV-Vis methods. The NO2 and SO2 concentrations peaked in the cold season, while their minimum levels were experienced in the warm season. The pollutant levels do not exceed the maximum allowable limit of the Cuban Standard 39:1999, i.e., 40 μg/m(3) and 50 μg/m(3) for NO2 and SO2, respectively. The lowest pollutant concentrations obtained in the warm season can be attributed to an increase in their removal via precipitation (scavenging) while to the decreased traffic density and industrial emission during the summer holidays (e.g., July and August).

MATÉRIAUX
Référence du produit
Marque
Description du produit

Adsorbants cartouches radiello, for sampling BTEX and VOCs (CS2 Desorption), matrix SS net (100 mesh, 5.8 mm diam.), activated with activated charcoal (30-50 mesh), pk of 20
Plaque de support triangulaire Radiello, pk of 20
Adsorbants cartouches radiello, for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISIL®, pk of 20
Corps diffusifs radiello, white, configured for general use, pk of 20
Adsorbants cartouches radiello, for sampling Ammonia (NH3), matrix microporous PE impregnated with phosphoric acid, pk of 20
Corps diffusifs radiello, yellow, configured for reduced sampling rates, pk of 20
Corps diffusifs radiello, blue, configured for sampling light sensitive compounds, pk of 20
Adsorbants cartouches radiello, for sampling BTEX and VOCs (thermal desorption), matrix SS net (3 x 8 μm, 4.8 mm diam.), Carbograph, pk of 20
Supelco
radiello Methylene Blue Calibration Standard for H2S (Hydrogen Sulfide), pkg of 100 mL
Abri extérieur radiello, pk of 10
radiello Vertical Adapter, threaded for standard use, pk of 20
radiello Barcode Labels, pk of 198
radiello BTEX/VOC Starter Kit, CS2 Desorption
Adsorbants cartouches radiello, for sampling Anaesthetic Gases/Vapors, matrix SS net with mix of mol sieve and activated charcoal (30-50 mesh), pk of 20
radiello BTEX/VOC Starter Kit, Thermal Desorption
Supelco
radiello BTEX Calibration Kit (Thermal Desorption)
radiello Filtration Kit, pk of 20
radiello Hydrogen Sulfide Starter Kit
radiello Empty Storage Tubes, polypropylene (with stopper), volume 12 mL, pk of 100
radiello On-Field Thermometer, Includes one standard Radiello vertical adapter (RAD122) for each thermometer, configured for standard use, pk of 3
radiello Anesthetic Gases and Vapor Sampler
Supelco
radiello Aldehyde Calibration Standard, 50 μg/mL each component in acetonitrile, pkg of 10 mL
Supelco
radiello BTEX Calibration Kit (CS2 Desorption)
radiello Empty Storage Tubes, glass (with stopper), volume 2.8 mL, pk of 100
radiello 1,3-Butadiene Starter Kit, Thermal Desorption, pkg of 1 kit (2 RAD141 adsorbing cartridges and barcode labels, 1 RAD1202 yellow diffusive body, 1 RAD121 triangular support plate, 1 instruction sheet)
radiello Clips, suspending Radiello triangular support plate, pk of 20
Corps diffusifs radiello, permeative, configured for anaesthetic gases and vapors, pk of 20
radiello On-Field Thermometer, Reader, pk of 1
radiello Replacement Mounting Strips, for use with Radiello Outdoor Shelter, pk of 100