Accéder au contenu
MilliporeSigma

Chemometric strategy for untargeted lipidomics: biomarker detection and identification in stressed human placental cells.

Analytica chimica acta (2014-12-07)
Eva Gorrochategui, Josefina Casas, Cinta Porte, Sílvia Lacorte, Romà Tauler
RÉSUMÉ

A lipidomic study was developed in a human placental choriocarcinoma cell line (JEG-3) exposed to tributyltin (TBT) and to a mixture of perfluorinated chemicals (PFCs). The method was based on the application of multivariate curve resolution-alternating least squares (MCR-ALS) to data sets obtained by ultra-high performance liquid chromatography coupled to time-of-flight mass spectrometry (UHPLC-TOF-MS) using an untargeted approach. Lipids from exposed JEG-3 cells were solid-liquid extracted and analyzed by UHPLC-TOF-MS in full scan mode, together with control samples. Raw UHPLC-TOF-MS data of the different cell samples were subdivided into 20 distinct chromatographic windows and each window was further organized in a column-wise augmented data matrix, where data from every sample was in an individual data matrix. Then, the 20 new augmented data matrices were modeled by MCR-ALS. A total number of 86 components were resolved and a statistical comparative study of their elution profiles showed distinct responses for the lipids of exposed versus control cells, evidencing a lipidome disruption attributed to the presence of the xenobiotics. Results from one-way ANOVA followed by a multiple comparisons test and from discriminant partial least squares (PLS-DA) analysis were compared as usual strategies for the determination of potential biomarkers. Identification of 24 out of the 33 proposed biomarkers contributed to the better understanding of the effects of PFCs and TBT in the lipidome of human placental cells. Overall, this study proposes an innovative untargeted LC-MS MCR-ALS approach valid for -omic sciences such as lipidomics.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Méthanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Acétonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Chloroforme, contains 100-200 ppm amylenes as stabilizer, ≥99.5%
Sigma-Aldrich
Méthanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Chloroforme, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains amylenes as stabilizer
Sigma-Aldrich
Chloroforme, suitable for HPLC, ≥99.8%, contains 0.5-1.0% ethanol as stabilizer
Sigma-Aldrich
Acétonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Chloroforme, contains ethanol as stabilizer, ACS reagent, ≥99.8%
Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
L-Glutamine, meets USP testing specifications, suitable for cell culture, 99.0-101.0%, from non-animal source
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Méthanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Acide heptafluorobutyrique, 98%
Sigma-Aldrich
Chloroforme, suitable for HPLC, ≥99.8%, amylene stabilized
Sigma-Aldrich
Acétonitrile, anhydrous, 99.8%
Sigma-Aldrich
Perfluorooctanoic acid, 95%
Sigma-Aldrich
2,6-Di-tert-butyl-4-methylphenol, ≥99.0% (GC), powder
Sigma-Aldrich
Pyruvate de sodium, powder, BioReagent, suitable for cell culture, suitable for insect cell culture, ≥99%
Sigma-Aldrich
Méthanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
L-Glutamine, ReagentPlus®, ≥99% (HPLC)
Sigma-Aldrich
Chloroforme, ReagentPlus®, ≥99.8%, contains 0.5-1.0% ethanol as stabilizer
Sigma-Aldrich
Méthanol, BioReagent, ≥99.93%
Sigma-Aldrich
Chloroforme, contains amylenes as stabilizer, ACS reagent, ≥99.8%
Sigma-Aldrich
Méthanol, Absolute - Acetone free
Sigma-Aldrich
Chloroforme, puriss. p.a., reag. ISO, reag. Ph. Eur., 99.0-99.4% (GC)
Sigma-Aldrich
Méthanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Acétonitrile, suitable for HPLC-GC, ≥99.8% (GC)