Accéder au contenu
MilliporeSigma
Toutes les photos(2)

Documents

54279-U

Supelco

BPE-DNPH solid phase extraction (SPE) Cartridge

volume 3 mL, bed B 270 mg (DNPH-coated silica), bed A 130 mg (2-BPE coated silica), pkg of 50 ea

Synonyme(s) :

BPE-DNPH cartridge tube

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Numéro CE :
Code UNSPSC :
12190000
Nomenclature NACRES :
NB.24

product name

BPE-DNPH Cartridge, volume 3 mL, bed B 270 mg (DNPH-coated silica), bed A 130 mg (2-BPE coated silica), pkg of 50 ea

Agence

ASTM® D5197
EPA IP-6A,TO-11A (BPE layer acts as a built-in ozone scrubber; not affected by moisture or high humidity conditions.)
NIOSH 2016 (BPE layer acts as a built-in ozone scrubber; not affected by moisture or high humidity conditions.)

Description

Dual-layer air sampling device.

Composition

bed A, 130 mg (2-BPE coated silica)
bed B, 270 mg (DNPH-coated silica)

Conditionnement

pkg of 50 ea

Technique(s)

active air sampling: suitable

Volume

3 mL

Application(s)

air monitoring
industrial hygiene

Température de stockage

2-8°C
2-8°C

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Our innovative BPE-DNPH cartridge is a dual-bed cartridge device designed for sampling of carbonyls in ambient, indoor and industrial atmospheres. Like traditional DNPH sampling devices, carbonyls (e.g. formaldehyde) are trapped onto our high purity 2,4-dinitrophenylhydrazine (LpDNPH) coated silica gel adsorbent and are converted to form stable hydrazone derivatives but offers the advantage of a 1,2-bis(2-pyridyl) ethylene (BPE) silica gel bed in front resulting in a built-in ozone scrubber that is not affected by high humidity or rainy conditions.

It is a well-known problem when sampling airborne carbonyls using DNPH-coated silica gel devices that ozone interferes with their analysis. To remove this ozone interference, traditional ozone scrubbing devices containing 1.5 g of Potassium Iodide (KI) are used in front of the DNPH device to trap the ozone, which causes negative ozone interference. In high humidity environments and rainy conditions, potassium iodide cartridges (or other multiple bed devices containing both potassium iodide and DNPH) result in sample loss, due to moisture condensation and collection inside the device.

Benefits:
  • Integrated ozone scrubber
  • No extra connections
  • No leaking cartridges
  • High Purity adsorbents for better accuracy in trace analysis
  • Low Background
  • Individual packaging in zip seal bag to maximize sample integrity
  • Suitable for NIOSH 2016, EPA TO-11A, EPA IP-6A and ASTM D5197
*Optional: Simultaneous measurement of ozone and carbonyls in one device

Application

BPE-DNPH Cartridge is used as a sampling device for the sampling of volatile organic compounds in surgical smoke samples analyzed by ultra-performance liquid chromatography technique.

Informations légales

ASTM is a registered trademark of American Society for Testing and Materials

Pictogrammes

Exclamation mark

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

Organes cibles

Respiratory system

Code de la classe de stockage

11 - Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Choose from one of the most recent versions:

Certificats d'analyse (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Health risk to medical personnel of surgical smoke produced during laparoscopic surgery
Dobrogowski M, et al.
International Journal of Occupational Medicine and Environmental Health, 28(5), 831-840 (2015)

Articles

Carbonyl compounds react within the DNPH cartridge to form immobilized hydrazones, which can be subjected to automated desorption and HPLC analysis with UV detection.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique