GE17-0944-10
SOURCE™ 15S
Cytiva 17-0944-10, pack of 10 mL
About This Item
Produits recommandés
ligand
sulfonate group
Description
Ion Exchanger Type (value)
Conditionnement
pack of 10 mL
Fabricant/nom de marque
Cytiva 17-0944-10
Matrice
polystyrene/divinylbenzene
Taille moy. des particules
15 μm
Taille des particules
15-15 μm
cleaning in place
1-14
working range
2-13
Adéquation
suitable for bioprocess medium (BioProcess medium. Process-scale quantities are available.)
suitable for bioprocess medium
Catégories apparentées
Description générale
Application
With its very high resolution, SOURCE™ 15S is suitable for polishing steps in both research and industrial applications.
Through the combination of high quality assurance standards and a patented manufacturing process, particle structure is consistent both bead-to-bead and batch-to batch.
As member of the BioProcess media range, SOURCE™ 15S meets industrial demands with security of supply and comprehensive technical and regulatory support.
Caractéristiques et avantages
- Mono-sized 15 um rigid beads gives Low back pressure and high flow rates allowing for high productivity
- Strong cation exchanger designed for high resolution polishing purification of Proteins, peptides and oligonucleotides
- High chemical stability allowing for wide range of working conditions with good resistance to cleaning conditions at high pH
Stockage et stabilité
Remarque sur l'analyse
Informations légales
Mention d'avertissement
Warning
Mentions de danger
Conseils de prudence
Code de la classe de stockage
3 - Flammable liquids
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Articles
This page shows Hydrophobic Interaction Chromatography (HIC) in a purification strategy.
Column, media, and sample preparation for Hydrophobic Interaction Chromatography (HIC) detailed with Cytiva media.
Protocoles
In this section the practical aspect of Reverse Phased Chromatography ( RPC) is discussed including media and column selection and eluent selection and preparation.
Selectivity of HIC medium from Cytiva is based on properties such as hydrophobicity, porosity and particle size.
This page discusses how to do a purification with SOURCE™ media from Cytiva.
This page discusses various aspects of sample preparation for chromatographic purification.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique