Accéder au contenu
MilliporeSigma
Toutes les photos(1)

Principaux documents

KVGLG04TT3

Millipore

Durapore® 0,22 µm, capsule Opticap® XL

inlet connection diam. 1.5 in., Opticap® XL 4, cartridge nominal length 4 in. (10 cm)

Synonyme(s) :

Opticap Gamma Compatible XL4 Durapore 0.22 μm 1-1/2 in. TC/TC

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme

Sélectionner une taille de conditionnement

3 EA
947,00 $

947,00 $


Veuillez contacter notre Service Clients pour connaître la disponibilité de ce produit.


Sélectionner une taille de conditionnement

Changer de vue
3 EA
947,00 $

About This Item

Code UNSPSC :
23151806

947,00 $


Veuillez contacter notre Service Clients pour connaître la disponibilité de ce produit.

Matériaux

PVDF
polyester support
polyethylene support
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap
silicone outer O-ring
silicone-coated EPDM rubber lead O-ring

Niveau de qualité

Conformité réglementaire

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

Stérilité

non-sterile

Mode de stérilisation compatible

gamma compatible

Gamme de produits

Opticap® XL 4

Caractéristiques

gamma compatible
hydrophilic

Fabricant/nom de marque

Opticap®

Paramètres

≤4.6 mL/min air diffusion at 2.75 bar (40 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.8 bar max. differential pressure (40 psid) at 25 °C (Reverse; intermittent)
2.8 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure

Technique(s)

sterile filtration: suitable

Longueur

7.7 in.

Largeur

3.3 in.

Longueur nominale des cartouches

4 in. (10 cm)

Diamètre

6.1 cm (2.4 in.)

Surface de filtration

0.18 m2

Diam. du raccord d'entrée

1.5 in.

Diam. du raccord de sortie

1.5 in.

Impuretés

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

Matrice

Durapore®

Dimension de pores

0.22 μm

Entrée

sample type liquid

Point de bulle

≥3450 mbar (50 psig), air with water at 23 °C

Raccords

1/4 in. drain/vent hose barb (with double O-ring Seal)
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)

Description générale

Device Configuration: Capsule

Conditionnement

Double Easy-Open bag

Autres remarques

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Notes préparatoires

Sterilization Method
3 autoclave cycles of 60 min @ 123 °C; capable of 45 kilogray (4.5 Megarad) gamma exposure; not in-line steam sterilizable
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Remarque sur l'analyse

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
TOC/Conductivity
After sterilization and a controlled water flush, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 ºC.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥500 mL

Informations légales

ASTM is a registered trademark of American Society for Testing and Materials
Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Clause de non-responsabilité

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.

Vous ne trouvez pas le bon produit ?  

Essayez notre Outil de sélection de produits.


Qu'est-ce que le programme Emprove® ?

Le programme Emprove® est un système fournissant une documentation exhaustive et précise de nos filtres, de nos composants à usage unique, de nos matières premières pharmaceutiques et de nos matériaux de départ.

Material Qualification Dossier

Gratuit - s'inscrire pour télécharger

Quality Management Dossier (Open Access)

Gratuit - s'inscrire pour télécharger

Operational Excellence Dossier

Disponible(s) sur abonnement ou moyennant des frais

En apprendre davantage sur les avantages qu'un abonnement au Programme Emprove® peut offrir
Pourquoi ces documents ne sont-ils pas disponibles ?
Les dossiers Emprove® contiennent des informations visant à soutenir le processus d'enregistrement et les activités d'évaluation des risques des fabricants pharmaceutiques ; ils contiennent des informations confidentielles. Veuillez nous contacter si vous souhaitez un accès.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Questions

Reviews

No rating value

Active Filters

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique