Pular para o conteúdo
Merck
  • [Simultaneous determination of five hypertoxic rodenticides in serum by gas chromatography-mass spectrometry].

[Simultaneous determination of five hypertoxic rodenticides in serum by gas chromatography-mass spectrometry].

Se pu = Chinese journal of chromatography (2015-07-18)
Huiqiu Huang, Xun Huang, Jingsun Yu
RESUMO

A fast analytical method based on gas chromatography-mass spectrometry (GC-MS) was established for the simultaneous determination of tetramine, fluoroacetamide, sodium fluoroacetate, gliftor I and gliftor II in serum. At pH 2.0, sodium fluoroacetate was derivatizated at room temperature for 5 min by using N,N-diethyl-p-phenylenediamine as the derivatization reagent and N, N'-dicyclohexylcarbodiimide as the catalyst. The derivative and other rodenticides were extracted with ethyl acetate and concentrated with nitrogen at 50 °C, then determined by GC-MS in selected ion monitoring (SIM) mode, and quantified with matrix-match standard solutions. The analysis was carried out on an ionic liquid chromatographic capillary column (SLB-IL59, 30 m x 0.25 mm x 0.20 µm, maximum temperature 300 °C) at a flow rate of 1.0 mL/min, and the five rodenticides were successfully separated in 15 min when temperature programming was used. The results showed that the calibration curves were linear in the range of 0.01-1.0 mg/L, except for fluoroacetamide (0.02-2.0 mg/L) and tetramine (0.02-10 mg/L), with correlation coefficients (R2) greater than 0.995, and the limits of detection (LODs) were 0.001-0.002 mg/L (S/N = 3). The recoveries were 84.0%-110.0% at three different spiked levels, and the relative standard deviations (RSDs) were 2.9%-7.5% (n = 6). The method is simple, accurate, highly sensitive and suitable for the detection of the five hypertoxic rodenticides in serum for toxicological purposes.

MATERIAIS
Número do produto
Marca
Descrição do produto

Supelco
Coluna de GC capilar SLB®-5ms, L × I.D. 30 m × 0.25 mm, df 0.25 μm
Supelco
Coluna de GC capilar SLB®-5ms, L × I.D. 20 m × 0.18 mm, df 0.18 μm
Supelco
Coluna de GC capilar SLB®-5ms, L × I.D. 60 m × 0.25 mm, df 0.25 μm
Supelco
Coluna de GC capilar SLB®-5ms, L × I.D. 30 m × 0.32 mm, df 0.25 μm
Supelco
Coluna de GC capilar SLB®-5ms, L × I.D. 10 m × 0.10 mm, df 0.10 μm
Supelco
Coluna de GC capilar SLB®-5ms, L × I.D. 30 m × 0.25 mm, df 1.00 μm
Supelco
Coluna de GC capilar SLB®-5ms, L × I.D. 30 m × 0.25 mm, df 0.10 μm
Supelco
Coluna de GC capilar SLB®-5ms, L × I.D. 15 m × 0.25 mm, df 0.25 μm
Supelco
Coluna de GC capilar SLB®-5ms, L × I.D. 15 m × 0.10 mm, df 0.10 μm
Supelco
Coluna de GC capilar SLB®-5ms, L × I.D. 30 m × 0.25 mm, df 0.50 μm
Supelco
SLB®-1ms Capillary GC Column, L × I.D. 60 m × 0.32 mm, df 0.25 μm
Supelco
SLB®-1ms Capillary GC Column, L × I.D. 15 m × 0.32 mm, df 0.25 μm
Supelco
SLB®-1ms Capillary GC Column, L × I.D. 30 m × 0.32 mm, df 0.10 μm