Pular para o conteúdo
Merck
Todas as fotos(1)

Key Documents

KGW1A1TTT1

Millipore

Polysep II 1.0/0.2/0.1 µm nominal, Opticap® XLT Capsule

Opticap® XLT 10, pore size 1.0/0.2/0.1 μm, cartridge nominal length 10 in. (25 cm)

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
23151806

Materiais

borosilicate glass fiber (BGF) membrane
mixed cellulose esters (MCE) membrane
polypropylene filter
polypropylene housing
polypropylene support
silicone seal

Nível de qualidade

conformidade reg.

FDA 21CFR177-182 (all component materials)

esterilidade

non-sterile

Compatibilidade de esterilização

autoclavable compatible

linha de produto

Opticap® XLT 10

Características

hydrophilic

fabricante/nome comercial

Opticap®

Parâmetros

1 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.5 bar max. differential pressure (50 psid) at 25 °C
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure

técnica(s)

prefiltration: suitable

comprimento nominal do cartucho

10 in. (25 cm)

device L

37.6 cm (14.8 in.)

device size

10 in.

filter filtration area

0.42 m2

diâm. conexão de entrada

1-1/2 in.

inlet to outlet width

15.2 cm (6.0 in.)

diam. conexão de saída

1-1/2 in.

Impurezas

≤0.5 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.5 EU/mL bacterial endotoxins (LAL test, sample aqueous extraction)

matriz

Polysep II

pore size

1.0/0.2/0.1 μm nominal pore size
1.0/0.2/0.1 μm pore size

conector

(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)

Procurando produtos similares? Visita Guia de comparação de produtos

Descrição geral

Device Configuration: Capsule

Características e benefícios

Triple Layer

Embalagem

Double Easy-Open bag

Nota de preparo

Sterilization Method:
3 autoclave cycles of Sterilization Method: 30min at 121°C; not in-line steam sterilizable

This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21CFR210.3(b)(6).

Nota de análise

Gravimetric Extractables: ≤ 145 mg per capsule after a 5 L flush and 24 hours in water at controlled room temperature.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥ 5 L

Outras notas

Directions for Use:

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer first page of Visual Inspection Guide and introduction section of Mixed cellulose esters Tech Brief
  • Storage Statement: Please refer Mixed cellulose esters Tech Brief
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

Informações legais

OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany
Polysep is a trademark of Sigma-Aldrich Co. LLC

Não está encontrando o produto certo?  

Experimente o nosso Ferramenta de seleção de produtos.


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica