Pular para o conteúdo
Merck
Todas as fotos(1)

Documentos Principais

HTS135M

Sigma-Aldrich

ChemiSCREEN Membrane Preparation Recombinant Human GPR41 Free Fatty Acid Receptor

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
41123201
eCl@ss:
32161000
NACRES:
NA.45
Preço e disponibilidade não estão disponíveis no momento.

descrição

GPCR Class A
protein target FFA3 / GPR41

Nível de qualidade

técnica(s)

radioligand binding assay (RLBA): suitable

nº de adesão UniProt

Informações sobre genes

human ... FFAR3(2865)

Descrição geral

Full-length human GPR41 cDNA
GPR41 is a GPCR that, along with GPR43, is activated by short chain carboxylic acids formate, acetate, proprionate, butyrate and pentanoate (Brown et al., 2003; Brown et al., 2005). Binding of these ligands to GPR41 selectively activates Gi to inhibit cAMP accumulation. Expression of GPR41 is prominent in adipose tissue, increases during differentiation of cultured adipocytes, and allows short chain carboxylic acids to stimulate leptin synthesis in adipocytes (Xiong et al., 2003). Millipore′s GPR41 membrane preparations are crude membrane preparations made from our proprietary stable recombinant cell lines to ensure high-level of GPCR surface expression; thus, they are ideal HTS tools for screening of GPR41 interactions with its ligands. The cell line exhibits a calcium response with EC50s of 51.5μM for sodium propionate. The membrane preparations exhibit EC50s of 30.1 μM for sodium propionate in a GTPγS binding assay.

Aplicação

Radioligand binding assay and GTPγS binding

Qualidade

1 unit = 5 μg
EC50 in GTPγS binding assay by sodium propionate: ~ 30.1 μM

forma física

Liquid in packaging buffer: 50 mM Tris pH 7.4, 10% glycerol and 1% BSA with no preservatives.
Packaging method: Membranes protein were adjusted to 1 mg/mL in packaging buffer, and dispensed at 1 mL/vial. Vials were rapidly frozen, and stored at -80°C.

Armazenamento e estabilidade

Maintain frozen at -70°C for up to 2 years. Do not freeze and thaw.

Nota de análise

Membranes are permeabilized by addition of saponin to an equal concentration by mass, then mixed with [35S]-GTPγS (final concentration of 0.3 nM) in 20 mM HEPES, pH 7.4/100 mM NaCl/10 mM MgCl2/0.5 μM GDP in a nonbinding 96-well plate. Unlabeled sodium propionate was added to the final concentration indicated in Figure 1 (final volume 100 μL), and incubated for 30 min at 30°C. The binding reaction is transferred to a GF/B filter plate (Millipore MAHF B1H) previously prewetted with water. The plate is washed 3 times (1 mL per well per wash) with cold 10 mM sodium phosphate, pH 7.4, then dried and counted.

One vial contains enough membranes for at least 200 assays (units), where one unit is the amount of membrane that will yield greater than 1000 cpm specific sodium propionate-stimulated [35S]-GTPγS binding.

The GPR41 membrane preparation is expected to be functional in a radioligand binding assay; however, the end user will need to determine the optimal radiolabeled ligand for use with this product.

Exoneração de responsabilidade

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica