HTS106M
ChemiSCREEN Membrane Preparation Recombinant Human MT2 Melatonin Receptor
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Produtos recomendados
descrição
GPCR Class A
protein target MT2
Nível de qualidade
técnica(s)
radioligand binding assay (RLBA): suitable
nº de adesão UniProt
Informações sobre genes
human ... MTNR1B(4544)
Descrição geral
FUNCTION: SwissProt: P49286 # High affinity receptor for melatonin. Likely to mediates the reproductive and circadian actions of melatonin. The activity of this receptor is mediated by pertussis toxin sensitive G proteins that inhibit adenylate cyclase activity.
SIZE: 362 amino acids; 40188 Da
SUBCELLULAR LOCATION: Cell membrane; Multi-pass membrane protein.
TISSUE SPECIFICITY: Expressed in retina and less in brain and hippocampus.
SIMILARITY: SwissProt: P49286 ## Belongs to the G-protein coupled receptor 1 family.
SIZE: 362 amino acids; 40188 Da
SUBCELLULAR LOCATION: Cell membrane; Multi-pass membrane protein.
TISSUE SPECIFICITY: Expressed in retina and less in brain and hippocampus.
SIMILARITY: SwissProt: P49286 ## Belongs to the G-protein coupled receptor 1 family.
Aplicação
Radioligand binding assay and GTPγS binding
forma física
Liquid in packaging buffer: 50 mM Tris pH 7.4, 10% glycerol and 1% BSA with no preservatives.
Packaging method: Membranes protein were adjusted to 1 mg/mL in packaging buffer, and dispensed at 1 mL/vial. Vials were rapidly frozen, and stored at -80°C.
Packaging method: Membranes protein were adjusted to 1 mg/mL in packaging buffer, and dispensed at 1 mL/vial. Vials were rapidly frozen, and stored at -80°C.
Armazenamento e estabilidade
Maintain frozen at -70°C for up to 2 years. Do not freeze and thaw.
Nota de análise
Membranes are mixed with radioactive ligand and unlabeled competitor (see Figures 1 and 2 for concentrations tested) in binding buffer in a nonbinding 96-well plate, and incubated for 1-2 h. Prior to filtration, an FC 96-well harvest plate (Millipore cat. # MAHF C1H) is coated with 0.33% polyethyleneimine for 30 min, then washed with 50mM HEPES, pH 7.4, 500mM NaCl. Binding reaction is transferred to the filter plate, and washed 3 times (1 mL per well per wash) with Wash Buffer. The plate is dried and counted.
Binding buffer: 50 mM Hepes, pH 7.4, 5 mM MgCl2, 1 mM CaCl2, filtered and stored at 4°C
Radioligand: [125I] Iodomelatonin (Perkin Elmer#: NEX-236)
Wash Buffer: 50 mM Hepes, pH 7.4, 500mM NaCl, filtered and stored at 4°C.
One package contains enough membranes for at least 200 assays (units), where a unit is the amount of membrane that will yield greater than 6-fold signal:background with [125I]-labeled Iodomelatonin at 0.2 nM
Binding buffer: 50 mM Hepes, pH 7.4, 5 mM MgCl2, 1 mM CaCl2, filtered and stored at 4°C
Radioligand: [125I] Iodomelatonin (Perkin Elmer#: NEX-236)
Wash Buffer: 50 mM Hepes, pH 7.4, 500mM NaCl, filtered and stored at 4°C.
One package contains enough membranes for at least 200 assays (units), where a unit is the amount of membrane that will yield greater than 6-fold signal:background with [125I]-labeled Iodomelatonin at 0.2 nM
Exoneração de responsabilidade
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica