Pular para o conteúdo
Merck
Todas as fotos(2)

Key Documents

GF71975065

Silver

foil, 10mm disks, thickness 0.05mm, as rolled, 99.95+%

Sinônimo(s):

Silver, AG000300

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Fórmula linear:
Ag
Número CAS:
Peso molecular:
107.87
Número MDL:
Código UNSPSC:
12141740
ID de substância PubChem:
NACRES:
NA.23

Ensaio

99.95%

forma

foil

fabricante/nome comercial

Goodfellow 719-750-65

resistividade

1.59 μΩ-cm, 20°C

diâmetro × espessura

10 mm × 0.05 mm

pb

2212 °C (lit.)

pf

960 °C (lit.)

densidade

10.49 g/cm3 (lit.)

cadeia de caracteres SMILES

[Ag]

InChI

1S/Ag

chave InChI

BQCADISMDOOEFD-UHFFFAOYSA-N

Descrição geral

For updated SDS information please visit www.goodfellow.com.

Informações legais

Product of Goodfellow

Código de classe de armazenamento

13 - Non Combustible Solids

Classe de risco de água (WGK)

WGK 3

Ponto de fulgor (°F)

Not applicable

Ponto de fulgor (°C)

Not applicable


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Ken-ichiro Matsumoto et al.
Biological & pharmaceutical bulletin, 28(11), 2029-2034 (2005-11-08)
A novel screening experiment, to find radioactive probes for non-invasive measurements of physiological functions in experimental animals, was tested using the in vivo multitracer analysis technique. The details of the efficiency of the detector settings used in the in vivo
Fan Yang et al.
Talanta, 84(4), 1099-1106 (2011-05-03)
In this paper, a compact and inexpensive light emitting diode induced fluorescence (LED-IF) detector with simplified optical configuration was developed and assembled in an integrated microfluidic device for microscale electrophoresis. The facile detector mainly consisted of an LED, a focusing
H H Wiebe et al.
Plant physiology, 59(2), 256-258 (1977-02-01)
Water potential was monitored at nine locations along single maize (Zea mays L.) leaf blades with aluminum block in situ thermocouple hygrometers. Water potential showed a continuous decrease toward the tip, with a 2- to 4-bar difference between leaf base
A Rupérez et al.
Talanta, 44(2), 213-220 (1997-02-01)
Surface-enhanced Raman scattering (SERS) spectrometry of the diuretic drug triamterene is discussed. The SERS-active substrate used is a silver foil etched with nitric acid. The influence of solvent and sample doping method on sensivity, intercept and shape of the calibration
M Dubiel et al.
Journal of synchrotron radiation, 8(Pt 2), 539-541 (2001-08-22)
The thermal expansion behaviour of silver fcc has been described by an anharmonic Einstein model using EXAFS data in the temperature range between 10 and 300 K. The linear expansion coefficient of a bulk silver foil agrees well with X-ray

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica