GF13111423

Tantalum

rod, 100mm, diameter 5.0mm, annealed, 99.9%

Sinônimo(s):

Tantalum, TA007930, Ta

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Fórmula empírica (Notação de Hill):
Ta
Número CAS:
Peso molecular:
180.95
Número MDL:
Código UNSPSC:
12141741
ID de substância PubChem:
NACRES:
NA.23
Preço e disponibilidade não estão disponíveis no momento.

pressão de vapor

<0.01 mmHg ( 537.2 °C)

Ensaio

99.90%

Formulário

rod

temperatura de autoignição

572 °F

fabricante/nome comercial

Goodfellow 131-114-23

resistividade

13.5 μΩ-cm, 20°C

C × diâmetro

100 mm × 5.0 mm

p.e.

5425 °C (lit.)

pf

2996 °C (lit.)

densidade

16.69 g/cm3 (lit.)

cadeia de caracteres SMILES

[Ta]

InChI

1S/Ta

chave InChI

GUVRBAGPIYLISA-UHFFFAOYSA-N

Descrição geral

For updated SDS information please visit www.goodfellow.com.

Informações legais

Product of Goodfellow

Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Lamentamos, não temos COA para este produto disponíveis online no momento.

Se precisar de ajuda, entre em contato Atendimento ao cliente

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Ulrich Dorn et al.
The Journal of arthroplasty, 29(4), 831-835 (2013-10-09)
This study compared the corrosion behavior of tantalum-coated cobalt-chromium modular necks with that of titanium alloy modular necks at their junction to titanium-alloy femoral stem. Tests were performed in a dry assembly and two wet assemblies, one contaminated with calf
[Tantalum dust as a contrast substance for laryngography and bronchography (a review of the literature)].
R M Rabinovich
Vestnik rentgenologii i radiologii, (1)(1), 77-79 (1981-01-01)
Xiao-kang Tang et al.
Zhongguo gu shang = China journal of orthopaedics and traumatology, 26(7), 617-620 (2013-10-19)
Incorrect treatment for femur head necrosis can cause collapse of femoral head and tresult in severe harm for the patients (especially for the patient with middle-aged and young). The structure and mechanics characteristics of tantalum rod is similar to bone
Clinical use of porous tantalum in complex primary total knee arthroplasty.
Neil P Sheth et al.
American journal of orthopedics (Belle Mead, N.J.), 38(10), 526-530 (2009-12-17)
J Black
Clinical materials, 16(3), 167-173 (1993-12-09)
A detailed literature search was carried out to define the current knowledge about the biological performance of tantalum. The pure metal appears, to a great degree, to be inert both in vivo and in vitro. Both the pure metal and